21
2. About broncolor Radio System
●
7.
Press the Measuring Button
6
.
The measured value (F-stop) will be displayed. Press the Measuring Button
6
again to fire all flashes in the same Studio Address and measure until the desired
F-stop is displayed.
The accumulated measured value (F-stop) and the cumulative count will be
displayed.
If you want to adjust the output power of each flash separately, go to Flash Power
Control Screen to make a measurement and adjustment.
In the Flash Power
Control Screen, the Multi (cumulative) flash measurement is not
available. (
P14)
NOTICE
● In case of the following, please follow “Cord Multi (Cumu.) Flash Mode” (
).
•
When firing the flash, if the flash brightness is lower than the ambient light, the meter
may fail to detect the light.
•
Rapid start fluorescent lamps and special lighting are sometimes mistaken for flash
and accidentally measured.
•
Even if the flash does not fire, when a sudden light change occurs in the light receptor,
measurement may be made.
•
The waveform of a flash bulb has a slight slope and there is a possibility that the light
meter cannot recognize the flash bulb.
● The EV scale cannot be displayed in the Radio Triggering Multi (Cumu.) Flash mode.
NOTE
● With broncolor radio system, individual flash triggering is not available for each Lamp
Address. All flashes in the same Studio Address will fire even if a particular Lamp
Address is selected. For measuring the flash individually, turn off the power of flash units
not in use. Or use the retracted lumisphere of L-858D to measure the light in front while
all flashes fire.
● For red-eye prevention and auto-flash light adjustment, some devices can pre-flash
before main flash burst. With the normal setting, the light meter will measure the pre-
flash bursts and not the main flash burst. To take a successful reading, activate the pre-
flash feature in the Tool Box. Please refer to the L-858D Operating Manual.
●
For radio frequencies, refer to “5. Radio Studio Address Frequencies”. (
[Measuring Screen]
Measured Value
(F-stop)
Cumulative Count