![Sekonic 401-858BR Operating Manual Download Page 23](http://html.mh-extra.com/html/sekonic/401-858br/401-858br_operating-manual_1236302023.webp)
15
2. About broncolor Radio System
●
3.
Press the Measuring Button
6
.
Flashes in the same Studio Address will fire, and the measured value (F-stop) will
be displayed.
The measured value is displayed in the main display and the Lamp Address display over
the selected Lamp Address in the Flash Power Control Screen.
4.
Touch [+]
or [-]
Button.
Touching the [+] or [-] Button will increase or decrease the power of the flash in 0.1
step for the selected Lamp Address. When holding the button longer (1 second),
the power will be adjusted in 1 (full) step.
The adjusted value will be displayed in the Adjusted Value area.
NOTICE
● The first flash triggered by light meter is the output power set in the flash units.
● Although up to +/-9.9 steps can be set, the adjustment must be within the upper and
lower limit of the power level specification of the flash unit.
●
The adjusted value will be reset to “0” when a new measurement is made, another Lamp
Address is selected, or the power is turned ON/OFF.
[Flash Power Control
Screen]
Lamp
Address
Display
Measured
Value
(F-stop)
Main
Display
[Flash Power Control
Screen]
[+] Button
[-] Button
Adjusted Value