9

Power / SetUp

This

 

condition

 

can

 

produce

 

an

 

open

 

circuit

 

Voltmeter

 

indication

 

of

 

satisfactory

 

Voltage,

 

because

 

the

 

resistance

 

of

 

degraded

 

continuity

 

is

 

difficult

 

to

 

detect

 

in

 

an

 

open

 

circuit.

 

Degraded

 

circuit/wire/

ground

 

connections

 

can

 

often

 

be

 

detected

 

by

 

detecting

 

the

 

difference

 

in

 

Voltage

 

at

 

the

 

load

 

when

 

OFF

 

and

 

when

 

ON.

 

Resistance

 

of

 

degraded

 

connections

 

will

 

prevent

 

full

 

V

oltage

 

when

 

the

 

circuit

 

load

 

(Indicator)

 

is

 

ON.

If

 

possible,

 

turn

 

the

 

Indicator

 

ON

 

and

 

OFF

 

while

 

monitoring

 

the

 

primary

 

power

 

Voltage.

 

Be

 

alert

 

for

 

a

 

significant

 

drop

 

in

 

Voltage

 

when

 

the

 

system

 

is

 

turned

 

ON.

For

 

example

 

if

 

the

 

open

 

circuit

 

Voltage

 

is

 

11.5

 

and

 

drops

 

to

 

10

 

V

 

or

 

9.5

 

V

 

etc.

 

when

 

the

 

indicator

 

is

 

turned

 

ON,

 

this

 

change

 

is

 

an

 

indication

 

that

 

the

 

system

 

battery

 

may

 

need

 

to

 

be

 

charged

 

or

 

that

 

continuity

 

of

 

the

 

conductors

 

and

 

connections

 

between

 

the

 

battery

 

to

 

the

 

indicator

 

may

 

have

 

been

 

degraded

 

by

 

corrosion

 

or

 

loosening,

 

etc.

4. During

 

testing,

 

move

 

the

 

Indicator

 

in

 

its

 

bracket

 

while

 

monitoring

 

the

 

Primary

 

Voltage.

The Indicator should not turn OFF.

 

Watch for any disturbance in the display (if the Power problem is

intermittent).

Voltage

 

readings

 

and

 

Indicator

 

Display

 

should

 

show

 

no

 

aberrations,

 

flicker,

 

etc.

If

 

movement

 

of

 

the

 

Indicator

 

affects

 

the

 

Primary

 

Power,

 

test

 

each

 

power

 

connection.

If

 

Primary

 

Power

 

is

 

delivered

 

via

 

a

 

plug

 

at

 

the

 

side

 

of

 

the

 

Indicator,

 

check

 

that

 

the

 

plug

 

is

 

the

 

correct

 

size

 

to

 

fit

 

the

 

barrel

 

and

 

also

 

the

 

center

 

pin.

 

Install

 

the

 

correct

 

size

 

plug,

 

if

 

this

 

connection

 

is

 

physically

 

sloppy

 

or

 

electrically

 

intermittent.

If

 

power

 

is

 

hard-wired

 

to

 

the

 

internal

 

Euro

 

connections

 

of

 

the

 

rear

 

panel,

 

remove

 

the

 

rear

 

cover

 

and

 

check

 

the

 

internal

 

power

 

wiring

 

for

 

connection

 

and

 

continuity.

The

 

Euro

 

connections

 

are

 

spring-loaded

 

with

 

an

 

internal

 

knife-edge.

 

The

 

insulation

 

of

 

the

 

wires

 

inserted

 

in

 

these

 

terminals

 

should

 

have

 

the

 

insulation

 

trimmed

 

back

 

to

 

expose

 

a

t  least

 

3/8

 

inch

 

or

 

10mm

 

of

 

bare

 

wire.

The

 

bare

 

wire

 

strands

 

would

 

be

 

twisted

 

so

 

that

 

there

 

are

 

no

 

"flying"

 

strands

 

and

 

so

 

that

 

the

 

twisted

 

wire

 

may

 

be

 

inserted

 

smoothly

 

into

 

the

 

Euro

 c

onnector

 

block

 

connection.

Depress

 

the

 

loading

 

tab,

 

insert

 

the

 

twisted

 

wire,

 

release

 

the

 

loading

 

tab.

 

Now,

 

give

 

the

 

wire

 

a

 

gentle

 

tug

 

to

 

seat

 

the

 

internal

 

clamp

 

and

 

assure

 

that

 

the

 

wire

 

does

 

not

 

slip

 

loose.

5. Internal dry cell batteries may be discharged to below minimum Voltage required to operate

 and will cause

the Indicator to turn Off

.

Summary of Contents for RINSTRUM K356

Page 1: ...itioner Voltage Converter for 24Volt to 48Volt systems SEKO FORKLIFT SCALE Accurate and Affordable Industrial Truck Scales RINSTRUM Model R320 323 K356 v4 16 DIGITAL SCALE INDICATOR Precision Static Weighing Lift Truck Scale Revised 25 June 2017 System Technical Specifications The SEKO Forklift Scale Modular Load Cell weighing system determines the load weight by sensing the weight on the forks Th...

Page 2: ...Side View Front View Side View with Boot Rear View Rinstrum R320 Scale Indicator Face View Rinstrum R320 Scale Indicator Rear View Installation 2 ...

Page 3: ...8Vdc from Truck Electrical Power may be attached via external plug or hardwired to internal Euro connector Connect power via Key Switch or directly to Battery Power Recommended in line fuse for truck electrical protection 2 0A Minimum For 24 36 48Vdc truck electrical systems contact Sales for Power Converter recommendations Installation 3 ...

Page 4: ...GND From Alarm Accessory OUT 1 Jumper Install jumper provided in Alarm Kit from PWR to COM Connect Alarm Cable RED wire to OUT 1 Connect Alarm Cable BLACK Wire to GND Check to assure spring clips grip wire not insulation Power SetUp DTR Connection Optional Normally Not Connected 12 9 9 9 12 12 Standard Rinstrum Rear Panel Wiring Options Alt Brown Alt Grey Yellow or Clear Yellow or Clear Alt Brown ...

Page 5: ...lay the weight of the load Liquid dangling and hanging loads can be difficult to weigh because the shifting load produces unstable inertial and gravitational stresses on the lifting mechanics Try to operate the truck to avoid sloshing swinging or bouncing of the load when lifting to weigh The Rinstrum Indicator can be set up for Live Weight weighing of unstable loads such as live animals See Secti...

Page 6: ...3 and NTEP certified S beam type load cells producing signals with 0 03 error The SEKO weigh module low friction mechanical design allows better than 0 1 displayed weight error in practice Mast tilt can cause weighing errors due to the altered gravitational vector producing strain on the scale load cells In normal truck operation this effect is small and generally not noticed However when 0 1 accu...

Page 7: ...fy this issue the instrument must be turned off When the instrument is turned back on the Passcode counter is reset to zero allowing the user to enter the correct Passcode SAFE PC Safe Passcode for Operator access allows partial access to Digital Setup ie only non calibration trade critical settings can be changed For the Safe Passcode SAFE PC to have any effect the FULL PC Full Passcode must also...

Page 8: ... Voltage polarity at the Indicator Connection Note Use a Voltmeter if possible to verify that the proper Voltage and polarity is present at all test points 2 If the wiring to the scale indicator is equipped with a fuse check the fuse Note The standard LTWS 1 hydraulic weighing systems normally consume less than 0 200 Amperes 200 milli Amp The purpose of a in line fuse is to protect the truck elect...

Page 9: ... problem is intermittent Voltage readings and Indicator Display should show no aberrations flicker etc If movement of the Indicator affects the Primary Power test each power connection If Primary Power is delivered via a plug at the side of the Indicator check that the plug is the correct size to fit the barrel and also the center pin Install the correct size plug if this connection is physically ...

Page 10: ...ecimals CAP 5000 RES 1 DUAL 60000 UNITS lb HI RES OFF CABLE 4 Navigation Press ZERO Button to select major setting Group Press TARE Button to select Setting Press SELECT Button to acivate selected Setting Use SELECT and PRINT Buttons to select and adjust Settings Use f OK Button to save the selected Setting f OK Button saving is temporary You MUST use the ZERO Button to go to END then press the TA...

Page 11: ...icator to turn the Indicator ON The Indicator should turn on automatically The Indicator will flash firmware codes and then display a static Weight If the forks are on the ground this number may be a negative weight Activate Setup and Calibration Mode FULL SETUP Codes bUiLD Hold down the small Power and f OK buttons together for about three 3 Seconds to enter SetUp Calibrate Mode The indicator wil...

Page 12: ... the Scale The display may show 005000 or Press SELECT another weight Set the Maximum Scale Weighing Capacity The Capacity should be set to one of the following amounts The label safe rated lift capacity of the machine Slightly above the maximum weight to be lifted in your application Press SELECT to select digit and PRINT to change the value of the selected digit The selected digit will flash SEK...

Page 13: ...m increments is 3000 CAP divided by RES should always be 3000 or less Press f OK to store the Display Resolution setting The Display will show rES The display may show 000000 without any Unit designation to select desired UNITS designation Press PRINT desired Options none g kg Lb t Press f OK to store the UNitS setting The Display will show UNITS Set High Resolution Option Press T Tare to select H...

Page 14: ...Transducer Cable Type If 6 Press PRINT and the display will show 4 Standard hydraulic forklift sensor is 4 wire cable Set Indicator Use Type Industrial NTEP OIML Press T Tare Display to select USE Press SELECT Display shows iNdUSt NtEP or OimL Default iNdUSt This is the correct setting Press f OK to store the USE setting The Display will show USE Press T Tare to select FiLTEr Set Filter None 2 5 1...

Page 15: ...ss PRINT shows 0 5 1 0 Press f OK to store the 0 5 1 0 setting The Display will show mOt iON Set Initial Zero OFF ON to select iNit Z Press T Tare Press SELECT key Display will show OFF If ON press PRINT until Display shows OFF Press f OK to store the OFF setting The Display will show iNit Z Set Zero Tracking OFF FASt mEd SLOw Press T Tare Display will show Z trAC Display will show OFF If ON press...

Page 16: ...Set Zero Tracking Band Z bANd Zero Band Press T Tare Press SELECT and the display will show 000000 and PRINT If other value adjust with SELECT until Display shows 000000 to store the setting The Display will The display will show r ENTrY Display will show OFF If ON press PRINT until Display shows OFF Press SELECT Display will show OFF If ON press PRINT until Display shows OFF Press f OK show Z bAN...

Page 17: ...ss 0 ZERO The Display will show LivE Press 0 ZERO The Display will show CLOC Press 0 ZERO The Display will show SPEC Press 0 ZERO Please contact Tech Support for the following setting instructions 307 321 4505 24 7 TEST Diagnostic Press 0 ZERO The display will show tESt TEST is a diagnostic mode and has no operator settings adjusted mV from the Transducer Analog Converter This number format is 0 0...

Page 18: ...Exit Programming Mode The display will show END Press 0 ZERO Save Settings Exit and Re Start Weighing Mode To Save and Exit Display will Press T Tare show SAviNG At this point Setup is complete Please proceed to Calibration Procedure Factory Reset NOT ADVISED ...

Page 19: ...19 ...

Page 20: ...ecords a known weight called the SPAN weight All subsequent weights are calculated using the ZERO and SPAN as reference points upon a linear vector Secure a known weight test load We recommend a weight of at least half of the maximum machine safe lifting capacity or use the maximum weight of your normal operation Heavier is better than lighter Preliminary Tasks Activate Calibration Mode Simultaneo...

Page 21: ...CT key and the display will show some flashing number Press T Tare to select ZErO ZERO to store the ZErO Lift the empty forks to the weighing point and press f OK ZERO setting The Display will show Z in P momentarily then display 0 lb 21 Cali brat ion ...

Page 22: ...r with the PRINT key Lift the test weight and stop at the height where you will normally weigh your loads Press f OK to store the SPAN SPAN setting The Display will show S in P momentarily then display a flashing weight Cali brat ion 22 to SAVE and Exit Press T Tare The display will show SAvinG and enter normal Weighing Mode Press to store the CLr L N setting The Display will show a flashing 0 lb ...

Page 23: ... ZERO button to go to CAL Press TARE button two times to go to SPAN Press SELECT button two 2 times to enter new SPAN calibration weight The display will show the previous SPAN calibration weight Use SELECT and PRINT buttons to enter an adjusted SPAN calibration weight If the scale reads high then decrease the SPAN calibration weight by approximately 1 2 50 of the error Lift the Test Weight and Pr...

Page 24: ...AL Press TARE button two times to go to SPAN Press SELECT button two 2 times to enter new SPAN calibration weight The display will show the previous SPAN calibration weight Use SELECT and PRINT buttons to enter an adjusted SPAN calibration weight If the scale reads high then decrease the SPAN calibration weight by approximately 1 2 50 of the error Lift the Test Weight and Press f OK button to stor...

Reviews: