6-8
6.4 DESIGN THE PLATEN RELEASE LEVER
Figure 6-6 shows dimensions of the release lever and its movement when the platen release lever is
released.
When designing the button or the lever that will operate simultaneously with the platen release lever, follow
the precautions below.
•
Design a stopper in the outer case to prevent to exceed 11 degree range of the platen release
lever’s motion and to be applied excessive force (29.4N (3kg)).
•
Design the button or the lever and its motion so that the platen release lever is pushed to an angle of
9 degrees of the released position. Design the stopper in the outer case to prevent the lever from
being damaged when the extraordinary force is applied to the platen release lever.
•
Design the button or the lever so that no load is constantly applied to it while the platen block is set.
Unit
:
mm
General
tolerance
:
±
0.5
Figure 6-6 External Dimensions and Motion of the Platen Release Lever
Platen set state
11
.7
The center of Lockarm rotation
Platen release position
9
°
Platen release lever
rotating position (max)
2.7
Parallel to printer mounting surface
22
.8
7.3
5.
1
The pressure area of Platen release lever
Platen open state
1.5
°
#1
#3
#2
27.8
#2
#1
#3
23
.8
5.
1
28
.8
7.3
1
1°
13.75
8.5
#1