Section 3: Pump Operations
Filter Instructions
2020 Heli-Pump Operations Manual
(Version F)
14
We Engineer Solutions
Filter Safety Precautions
•
Do not drain fuel on to the ground. Drain into a container which
can be closed.
•
Have trays and absorbent materials available in case of a spill.
•
Wear rubber gloves when replacing cartridges as some fuel
additives are toxic.
•
Fire extinguishers and other fire fighting equipment must be kept
close by.
•
If tools are required, use only non-sparking tools.
•
Rules prohibiting smoking and open flames in the area must be
established and strictly enforced.
Caution
Do not use spin-on absorptive cartridges with pre-mixed fuels containing anti-icing additives.
On canister-type filters, check the bottom of the housings frequently when using fuel containing
anti-icing additives. Stagnant water in the bottom of the filter housing can absorb large amounts
of anti-icing additives and must be periodically drained off.
Spin-On Filter
Important Note
Used filter cartridges are a fire hazard. They must be enclosed in a metal or approved fuel
container.