Section 9: General Repairs
Bambi MAX Shell Repairs
2016 Bambi MAX Service Manual
–
Models 1518-3542
(Version E)
63
We Engineer Solutions
Repairing in High Humidity
In conditions of high humidity, a proper technique is essential for securing the bond strength desired. The
presence of surface moisture can destroy the effectiveness of the cemented bond.
The evaporation of solvent from the adhesive may reduce surface temperature below the dew point resulting
in condensation of water vapour on the surface of the adhesive. This is often visible as fogging or a milky
white appearance on the surface.
The use of a solvent to clean the surface prior to cementing can also reduce temperatures below the dew
point.
To overcome the high humidity problem, raise the temperature of the patch area. This can be accomplished
with a warm air fan.
Warning
•
Glue vapours are highly explosive! Explosive vapours may occur causing fire and/or
injury. Keep away from all sparks, flame, lighters or cigarettes.
•
Solvent and glue are both extremely hazardous. Use solvent and glue under well
ventilated conditions only.
•
Use an approved respirator mask to avoid breathing fumes.
•
When using a warm air fan, either use one which is rated EXPLOSION PROOF or
make sure that there is a steady flow of air past the work area to remove fumes as they
are generated.