85
www.seuservice.com
17. TROUBLESHOOTING
In order to prevent electric shock and short circuit, be sure to turn power off
before performing work.
Be careful so as not to damage wirings. Damaged wiring can cause electric
shock or short circuit.
After removing the cause of the functioning of the Circuit Protector, reinstate
the Circuit Protector. Depending on the cause of the functioning, using the
Circuit Protector as is without removing the cause can cause generation of
heat and fire hazard.
In case a problem occurs, first check wiring connector connections.
PROBLEMS
CAUSE
COUNTERMEASURES
With Main SW
ON, no activation.
The color on PTV
screen is
incorrect.
Color deviation
on PTV screen
.
Power is not supplied.
Power supply/voltage is not correct.
The Circuit Protector functioned
due to the momentary overload.
Image adjustment is inappropriate.
Affected by peripheral machines or
the building's steel frames.
Securely insert the power plug into the plug
socket.
Make sure that power supply/voltage is
correct.
After eliminating the cause of overload,
reinstate the AC Unit's Circuit Protector
(see 5 , Section 6, Refer to the following).
Adjust appropriately (see Sec.14).
Perform convergence adjustment
(see Sec. 14).
Change installation direction or position.
Move the machine which causes the
problem.
TABLE 17 a
FIG. 17 a
CIRCUIT PROTECTOR
Functions due to the activation of
bimetal. To restore the function,
wait for approximately one minute
or longer until the bimetal cools
off. (Press the Button.)
CIRCUIT PROTECTOR
Summary of Contents for 18 Wheeler American Pro Trucker
Page 99: ...95 www seuservice com 1 TOP ASSY PTR DX D 1 2 Inside the door Position of...
Page 105: ...101 www seuservice com 6 ASSY MAIN CABINET PTR 1000 D 1 4...
Page 106: ...102 www seuservice com 6 ASSY MAIN CABINET PTR 1000 D 2 4...
Page 109: ...105 www seuservice com ASSY STEERING UNIT...
Page 110: ...106 www seuservice com ASSY HANDLE MECHA...
Page 111: ...107 www seuservice com 7 ASSY SUB CABI PTR 1100 D 1 3...
Page 118: ...114 www seuservice com 12 AC UNIT PTR 1060 D 1 2...
Page 120: ...116 www seuservice com 13 ASSY PILLAR L PTR 1070 D 1 2...
Page 122: ...118 www seuservice com 14 ASSY PILLAR R PTR 1075 D 1 2...
Page 125: ...121 www seuservice com 16 ASSY COINCHUTE TOWER PTR 1200 D 1 2...
Page 128: ...124 www seuservice com 18 ASSY MAIN BILLBOARD PTR 1500 D 1 2 OPPOSITE SIDE...
Page 130: ...126 www seuservice com 19 ASSY HIGH LOW BACK SHIFTER PTR 2100 D 1 2 For EARTH...
Page 132: ...128 www seuservice com 20 ASSY ACCEL BRAKE SPG 2200 D 1 2...
Page 146: ......