SEELEY INTERNATIONAL
- SERVICE GUIDE
|
17
SETTINGS MENU
cont
ILL1838-A
The COOLER menus include settings or
information related to the specific Seeley
International cooling products installed within
the system.
More information about the specific settings
of these products is provided in the separate
product installation guide.
About Appliance
Displays information such as model number,
serial number and software version for all
coolers connected to the controller.
Min/Max Set Temperature
Defines the maximum and minimum
temperature values.
Night Quiet Mode
Restricts fan speed to a specified level during
a specified night period.
Humidity Control (when Air sensor is
connected)
Set desired humidity levels.
Manual Drain
Turns cooler off and drains the tank.
Pad Flush
Turns cooler off and runs pump for a specified
amount of time.
Drain And Dry
Cooler will drain and fan will run for 1 hour
every day at a specified time.
Water Manager
Select the preferred water management
method:
• Salinity Measurement - replaces water when
Salinity level reaches set point.
•
Timed Drain - drains Tank After 8 tank fill cycles or
every 1-2 hours (system dependant).
• No Drain Control - salinity control external to
electronics eg. continuous bleed.
• No Water Thermostatic - allows Thermostatic
control in VENT mode. No water present. Cooling
performance is limited.
Weather Seal Open Speed
The cooler fan will turn on at the specified
weather seal opening speed for the first 10
seconds each time it starts up. It will then
return to the set fan speed.
Prewet
When COOL mode is activated, the pump will
run for 90 seconds before the fan is switched
on.
Salinity Level
Sets the salinity level at which the tank will
drain in “SALINITY MEASUREMENT” mode.
Tank Drain Delay
Sets the time delay before the drain valve
opens after the pump in the cooler is turned off.
Autoclean
Select the preferred cleaning interval (50 / 100
/ 200 hrs). At 8.00am after the selected running
hours has been reached, the cooler will drain
the tank, fill with fresh water and operate the
pump for 5 minutes. When complete, drains
the tank and returns to previous operation
mode. This feature is only available on
selected Breezair products.
MANAGING FAULTS
When a component in the system experiences
a fault, the controller will be notified and a
fault screen will appear. The operator can then
chose to resolve the issue or ignore it.
ILL1863-A
COOLER MENU
SERVICE MENU
The SERVICE menu contains information and
functions for competent service personnel.
For more details refer to the MANAGING
FAULTS section.