Cables used for the MagIQ Touch Controller
are 26AWG, 7/016, 6 core flat.
•
20m/66
"
cable is supplied with each Seeley cooler or heater
•
40m/131
"
cable is also available
• Supplied cables should not be altered.
ALWAYS route cables at least 300mm / 12
"
away from regular
power cables and high power machines. Cross over power cables
at right angles.
Important!
Where maximum cable lengths are exceeded, or cables are not
routed in accordance with our recommendations Seeley technical
support is not available and the product warranty may be voided.
Note!
The term “component” (Seeley International cooler or heater)
will be used in this document to describe any separate device,
such as a cooler, heater or sensor, which is to be connected
to the MagIQ Touch Controller.
CABLE LENGTHS
40m / 131"
MAX
ILL1583-A
Seeley International
cooler or heater