6
|
ILL2150-A
ILL746-B
D
A
B
C
E
F
G
A = Drain Valve
B = Power Lead (plugs into control box)
C = O-Ring
D = Tank
E = Nut
F = Drain Adaptor
G = Lock Nut
INSTALLING THE DRAIN VALVE (OPTIONAL)
Water drained from the cooler must be carried away to a
suitable discharge point in accordance with local regulations.
Important!
Never drain water from the cooler directly on to the
roof.
Make sure the “O”-ring (C) is fitted before placing the drain
valve into the hole. Screw the nut (E) up tightly by hand
underneath to locate the drain valve. Locate the drain adaptor
(F) up against the bottom of the drain valve thread and secure
with the second, larger nut (G). Make sure that you use the
correct drain adaptor. Make sure the drain water discharge
flows freely away from the cooler.
Important!
Do not over-tighten plastic fittings.
Remove Shorting pins then connect the drain valve cable to the
cooler electronics box.
An optional Water Manager Kit, Part # 073392, can be supplied
with the cooler or at a later date if required. The water manager,
which is fully automatic, is controlled by the cooler control
electronics combined with your Braemar wall control. The
system is designed to ensure that the water is always fresh,
maintains your cooler in good condition and ensures optimum
cooling performance.
Refer to the installation manual provided with the wall controller
for instructions on installing the controller. Coolers are supplied
with a 20m (66’) control cable. Longer cable lengths are
available from Seeley.
Important!
The maximum cable length allowed from the
MagIQtouch controller to the first cooler is 25 metres (82’). For
any additional coolers added into the system with a link module
the maximum allowed length is 40 metres (131’). Therefore,
failure of the product or components to operate correctly due
to modification to supplied
cables, or the use of non-approved
cables will NOT be accepted under the Manufacturer’s
Warranty.
We have this cable available through our sales order office and
spare parts outlets in the following lengths:
Part No. Length Details
833880
20m
MagIQtouch Controller Cable (No Ferrite)
823553
20m
MagIQtouch Controller Cable (With Ferrite)
862873
1.5m
MagIQtouch Controller Cable (No Ferrite)
861265
3m
MagIQtouch Controller Cable (No Ferrite)
864396
30m
MagIQtouch Controller Cable (With Ferrite)
864402
40m
MagIQtouch Controller Cable (With Ferrite)
CONNECTING THE MAGIQTOUCH/
MAGIQCOOL CONTROLLER OR SWITCH
PLATE
MAGIQCOOL WALL CONTROL DISPLAYS
“SERVICE”
If on initial Installation of a Cooler, or after the wall control has
been changed, the word “SERVICE” appears on the MagIQcool
Wall control screen and the unit does not respond to the
pushing of any buttons even though the backlighting responds.
This is easily rectified and means that communication needs
to be established between the Wall control and the electronic
controller inside the Cooler.
To establish communications simply push and hold the “DOWN”
button until the word “SERVICE” disappears from the screen
and the temperature appears. This may take up to 10 seconds.
Once communications has been established the unit can be
operated.
IMPORTANT
Do not press up when in service mode. Unit will not start
ILL3010
ILL2150-A
ILL2122-B