OPERATION cont.
ERROR DISPLAY
Your High Wall air conditioner includes abnormal operation detection hardware
and software. If the unit enters an abnormal state, the temperature indicator on
the fascia display will blink to display a corresponding error code.
Error codes and their meanings are shown below:
Note: if there are other error codes displayed, please contact Seeley qualified
service agents for details.
Please note the error code displayed when contacting Seeley service.
FAULT CONDITIONS
If the below conditions should occur, please turn off the air conditioner and
isolate its power immediately, and then contact the Seeley qualified service
agents for assistance.
Power cord is overheating or damaged.
Abnormal sound during operation.
Circuit breaker is continually tripping.
Burning smell is noticed.
Indoor unit is leaking condensate
Error Description
It can be reset by restarting the unit. If not, please
contact Seeley qualified service agents.
It can be reset by restarting the unit. If not, please
contact Seeley qualified service agents.
It can be reset by restarting the unit. If not, please
contact Seeley qualified service agents.
It can be reset by restarting the unit. If not, please
contact Seeley qualified service agents.
DRED mode 1 (full shut down), mode 2 (50% power) or
Mode 3 (75% power) signal received from Power Grid
Error Code
E1
E5
E8
H6
d1, d2, d3
OPERATION cont.
Indoor
display
ERROR DISPLAY
Your High Wall air conditioner includes abnormal operation detection hardware
and software. If the unit enters an abnormal state, the temperature indicator on
the fascia display will blink to display a corresponding error code.
Error codes and their meanings are shown below:
Note: if there are other error codes displayed, please contact Seeley qualified
service agents for details.
Please note the error code displayed when contacting Seeley service.
FAULT CONDITIONS
If the below conditions should occur, please turn off the air conditioner and
isolate its power immediately, and then contact the Seeley qualified service
agents for assistance.
Power cord is overheating or damaged.
Abnormal sound during operation.
Circuit breaker is continually tripping.
Burning smell is noticed.
Indoor unit is leaking condensate
Error Description
Defrost status entered. This is a normal occurrence in
HEAT mode.
Please contact Seeley qualified service agents.
Please contact Seeley qualified service agents.
Please contact Seeley qualified service agents.
It can be reset by restarting the unit. If not, please contact
Seeley qualified service agents.
DRED mode 1 (full shut down), mode 2 (50% power) or
Mode 3 (75% power) signal received from Power Grid
Error code (example only)
Error Code
Heating icon ON 10s,
OFF 0.5s
F1
F2
C5
H6
d1, d2, d3
Error code (example only)
11