SAFETY
AIR FILTER
Always isolate power for the air
conditioner from electricity mains
before cleaning or maintenance.
It is important to check and clean the
air filter as per the Maintenance
Schedule. A dirty air filter will not allow
the correct amount of clean air to pass
through your air conditioner, resulting
in poor performance and increased
running costs. Please follow the below
steps:-
1. Pull the front panel out and up from
the bottom as shown.
2. Remove the air filter and clean with
a vacuum cleaner. If it is very dirty,
wash with mild soapy water (below
45°C) and wipe off. Dry in the shade.
3. Make sure it is completely dry
before refitting it. You should never
operate the air conditioner without the
air filter in place.
INDOOR COIL (REFER PAGE 2)
OUTDOOR UNIT
REFRIGERANT
PLEASE REFER TO THE NEXT
PAGE FOR THE MAINTENANCE
SCHEDULE
Ensure drain connections are checked
on an annual basis (as set out in the
Maintenance Schedule below). Drains
can become blocked by all types of
insects, and rats have been known to
chew through the drain to get to the
water in the pipe.
The Outdoor unit has either one or two
fans, it draws air through the appliance
to expel the heat generated during the
cooling cycle. We recommend
checking that plants haven't grown into
or around the air intake or outlet, along
with other debris that may build up
over time, namely, leaves and the like.
A lack of refrigerant, due to a leak, will
cause the compressor to overheat and
expire prematurely. You will notice a
decline in cooling effect and an
increase in power consumption.
Therefore, having a qualified, licensed
technician service your air conditioner
will save you money in the long term.
(REFER PAGE 2)
MAINTENANCE & SERVICE
LSHVD1S Series Inverter Unit
12