background image

ST-HDoC / ST-HDoC-MM 

CVI/TVI/AHD & ANALOG TEST METER 

WITH OPTIONAL SDI & DIGITAL MULTIMETER 

(Optional Features: ST-HDoC-MM) 

User Manual V 

1.2

www.nacebrands.com

 

www.securitytronix.com

 

Summary of Contents for ST-HDoC

Page 1: ...ST HDoC ST HDoC MM CVI TVI AHD ANALOG TEST METER WITH OPTIONAL SDI DIGITAL MULTIMETER Optional Features ST HDoC MM User Manual V 1 2 www nacebrands com www securitytronix com ...

Page 2: ... warranty period Please see the last page of the manual for warranty information Batteries come disconnected to ensure they do not drain during shipment Please connect the battery prior to powering on the ST HDoC If there is any question or problem while using the ST HDoC HD tester please contact our SecurityTronix technical support department at 1 800 688 9282 option 3 and then option 2 Visit our...

Page 3: ...o level meter Optional 18 3 3 4 Video setting 18 3 3 5 PTZ address search 19 3 3 6 CVI camera test Optional 20 3 3 7 TVI camera test Optional 21 3 3 8 AHD camera test Optional 21 3 3 9 SDI camera test Optional 25 3 3 10 Cable tracer Optional 22 3 3 11 Cable test Optional 22 3 3 12 Digital multimeter Optional 23 3 3 13 Optical power meter Optional 31 3 3 14 Visual fault locator Optional 31 3 3 15 T...

Page 4: ...3 6 LED lamp 34 4 Specifications 34 4 1 General Specifications 34 4 2 Multimeter specifications 37 ...

Page 5: ...measuring a live circuit do not touch any unused terminals If the value to be measured is unknown while using the manual range set the range selector to the highest position Always be careful when working with AC or DC voltages since you could be injured or killed by voltage going through your body Keep your fingers behind the probe barriers while measuring Do not touch the metal probes while taki...

Page 6: ...generator new added gray scale image test PAL NTSC multi system color bar video generator Eight system switchable transmit receive eight system color bar HD CVI camera image display coaxial PTZ control and call up the camera OSD menu HD TVI camera image display coaxial PTZ control and call up the camera OSD menu AHD camera image display coaxial PTZ control and call up the camera OSD menu TDR cable...

Page 7: ...d maintenance work 2 3 2 Video level meter CVBS Performs NTSC and PAL video amplitude signal measurements for PEAK to PEAK SYNC level COLOR BURST and CHROMA level Video signal PEAK to PEAK level For NTSC format the video signal level is 140 15IRE For PAL format the video signal level is 1000 200mV If the level is too low it will cause the image to lose quality and limit the distance it will travel...

Page 8: ...bar generator The newly added gray scale image test allows the tester to test the monitor for optimal gray scale performance The tester sends out color bars via its BNC output to the monitor This is used to test for a problem in the cable going from the camera back to the monitoring area 2 3 5 DC12V 1A output power The unit can power a camera with 12V DC 1A power output from the tester It is helpf...

Page 9: ...upports 720p 25 30 50 60fps 1080p 25 30fps The features are live video and coaxial PTZ control including calling up the camera s OSD menu 2 3 11 TVI camera test This displays an HD TVI camera image It supports 720p 25 30 50 60fps 1080p 25 30fps The features are live video and coaxial PTZ control including calling up the camera s OSD menu 2 3 12 AHD camera test This displays an HD TVI camera image ...

Page 10: ...ring ranges 2 3 16 Optical Power Meter Optical power testing is not available with the ST HDoC series testers 2 3 17 TDR open circuit TDR testing is not available with the ST HDoC series testers 2 3 18 Visual fault locator Visual Fault Locator is not available with the ST HDoC series testers 2 3 19 LED lamp Press the LED On Off button to use the LED flashlight 2 3 20 F1 F2 User defined shortcut ke...

Page 11: ...V DC 3000mAh typically not plugged in 5 3 foot BNC test cable 6 18 inch RS485 test cable with alligator clips 7 Multi meter test leads red and black only for the ST HDoC MM model 8 3 foot camera powering cable 9 18 inch 3 5mm audio microphone or speaker cable with alligator clips 10 Carrying case and hanging strap with front accessory pouch 11 User s manual ...

Page 12: ...ST HDoC ST HDoC MM 8 2 5 Front Panel ...

Page 13: ...l while setting parameters close or decrease the aperture 10 Upward Select the item which will be set or add the value of the parameter Tilt the PTZ upward 11 User defined key can be customized for quick access functions 12 LED Lamp 13 Rightward Enter the sub menu or select the parameter whose value will be changed Add the value of the parameter Pan the PTZ right 14 Digital multimeter voltage curr...

Page 14: ...ST HDoC ST HDoC MM 10 20 WIDE zoom out the image 21 Near focus Focus the image near 22 Far focus Focus the image far 23 Menu key 24 TELE zoom in the image ...

Page 15: ...ace Optional 28 TDR cable open circuit and short circuit test Optional 29 12V DC 1A output 30 SDI test port BNC interface Optional 31 LED lamp 32 RS485Interface RS485 communication for PTZ 33 Network cable Telephone cable test port 34 Device charging port Mini USB 35 No function 36 No function 37 Audio input for testing audio pickup equipment 38 Reset the device to factory original settings ...

Page 16: ...er adapter for the device At the first time of use the batteries should be completely exhausted and then recharged for 4 or 5 hours The Charge Indicator lights red when charging the battery and turns off automatically when charging is complete Notice When the Charge Indicator turns off the battery is approximately 90 charged Do not charge for more than one hour after the indicator has turned off P...

Page 17: ...er s RS485 interface Note positive and negative connection of the cable 3 3 OSD Menu Press the key to turn the tester on Press the key again to turn off you can also set the meter to automatically power off Enter the menu choose one function to enter then short press the key While in the main menu pressing quickly switches to the different menu lists While in the main menu continuously press the k...

Page 18: ...e tester and open the PTZ controller app From this menu you can view the video stream as well as control PTZ movements From within the PTZ app you can also configure parameters such as Protocol Baud Rate Address Pan Tilt speed Preset call and recall PTZ controller parameter settings In the PTZ CONTROLLER app as shown in above photo press the key to enter the parameter settings Press the key to mov...

Page 19: ...54 the address settings must be consistent with that of the PTZ camera being tested E Pan speed Set the pan speed of the PTZ camera 0 63 F Tilt speed Set the tilt speed of PTZ the camera 0 63 G Set preset position Set PS Move the yellow cursor to SET PS to save the preset position number 1 128 Press the key To accelerate the value change then press the key to save H Call the preset position Go PS ...

Page 20: ...TZ controller submenu Press the key to move the yellow cursor to GO PS Press the key to select the desired preset number Then press the key to call the preset position The camera moves to the preset position immediately Lens zoom focus and iris is will automatically change to the preset parameters provided the camera is equipped with these features Tips Preset position setting is saved in the PTZ ...

Page 21: ... enter The tester s color bar generator supports both PAL and NTSC format color bars Press the key or to move the cursor to Format LCD or Type Format can be switched between NTSC or PAL LCD video output can be changed from Video output mode Color bar out to a test monitor or Input mode to test analog CVBS incoming signals through the BNC port Short press the to turn off the menu and full screen th...

Page 22: ...y through the received color bar B You can send one of several different color pallets to determine if the display monitor is calibrated properly C Send gray scale test bar to debug a monitor s grayscale performance 3 3 3 Video level meter The ST HDoC ST HDoC MM is not equipped with the Video level meter 3 3 4 Video setting Press to access the menu press to enter LCD brightness contrast color satu...

Page 23: ...efore searching Otherwise all the PTZ cameras in the same system will be programmed at the same time Press to select and then press to enter device settings Select Address search press to select ON or OFF then Press to save The PTZ address search function will now display on the main menu Note When the ST HDoC is turned off the Address search is defaulted to OFF Press the key to set protocol and b...

Page 24: ...ontrol button to adjust the Speed Dome Camera Press the button to quit 3 3 6 CVI camera test Connect a CVI camera to the ST HDoC s AHD CVI TVI interface Press the key to enter the tester s main menu then press the keys to select CVI Press the key to enter CVI test PTZ control over coaxial cable if the camera is equipped Press key to open the menu then press key to switch the control between coaxia...

Page 25: ...o enter TVI test For PTZ control and camera OSD menu operation instructions please refer to 3 3 6 CVI camera test 3 3 8 AHD camera test Connect an AHD camera to the ST HDoC s AHD TVI CVI interface Press key to enter the tester s main menu then press key to select AHD Press key to enter AHD test For PTZ control and camera OSD menu operation instructions please refer to 3 3 6 CVI camera test ...

Page 26: ...oller 3 3 10 Cable Tracer The ST HDoC ST HDoC MM is not equipped with the Cable Tester Function 3 3 11 Cable tester Press the key to enter the tester s main menu then press the key to select then press to enter Testing a LAN or telephone cable Connect a LAN or telephone cable to the ST HDoC tester and the other end into the cable tester marked No 255 Once connected the cable type and sequence of w...

Page 27: ... tester s main menu then press the key to select then press to enter 1 Function Button Auto range Data hold Relative measuring Function select Manual range 2 SYMBOLS U DC Voltage Measuring U AC Voltage Measuring A DC Current Measuring A AC Current Measuring Ω Resistance Measuring Continuity Testing Diode Testing Capacitance Measuring ...

Page 28: ...p to 10Amps Over range The current measurement is over the rated value switch to auto range to obtain the proper measurement 3 OPERATING INSTRUCTION A DC Voltage Measuring a Connect the black test lead to the COM jack and the red test lead to the V Ω jack b Press to select U to enter the DC voltage measurement c Auto range by pressing the key and manual range by press pressing the keys d Manual ra...

Page 29: ...ack for a maximum of 660mA current For a maximum of 10A move the red lead to the 10A jack b Press to select A to enter the DC current measurement Manually adjust the range by pressing the buttons Manual range 0 000mA 6 6mA range 00 00mA 66 00mA range 000 0mA 660 0mA range WARNING You can t input the voltage which more than 660V AC it s possible to show higher voltage but it may destroy the inner c...

Page 30: ...660mA over current will destroy the fuse and will damage the meter The maximum current of 10A socket is 10A over current will destroy the meter and potentially cause bodily harm D AC Current Measuring Only Manual range a Connect the black test lead to the COM jack and the red test lead to the mA jack for a maximum of 660mA current For a maximum of 10A move the red lead to the 10A jack b Press to s...

Page 31: ...ximum current of 10A socket is 10A over current will destroy the meter and potentially cause bodily harm Applying DC voltage while in AC mode will damage the test meter E Resistance Measuring a Connect the black test lead to the COM jack and the red test lead to the V Ω jack b Press to select Ω to enter the Ω measurement Auto range by pressing the key and manual range by pressing the buttons Manua...

Page 32: ...ance less than about 50Ω the built in buzzer will generate an audible tone e You can also get reading from the LCD indicating continuity G Diode Testing a Connect the black test lead to the COM jack and the red test lead to the V Ω jack b Press to select to enter the diode test c Connect test red lead to the anode of the diode under test d Connect the black lead to the cathode of the diode under t...

Page 33: ...ure that the capacitor has been fully discharged d The capacitance will be displayed on the LCD Note a The capacitance of a capacitor should be tested separately do not test a capacitor while it is connected to a circuit b To avoid electric shock be sure the capacitors have been fully discharged before measuring the capacitance of a capacitor c While testing the capacitance of a capacitor up to 66...

Page 34: ...yellow Voltage protection Input voltage not to exceed 660V AC DC applying overvoltage to the tester will damage it and may cause bodily harm Resistance Continuity Diode PTC component Protection Incorrect input voltage will trigger the protection mode which is only suitable for a short time If the input voltage is over 600V it will damage the tester and may cause bodily harm mA current fuse range 2...

Page 35: ...nitor Press to select then press to enter Press to choose the baud rate of the RS485 interface baud rate must match the device being monitored DVR PTZ controller etc The DVR or Control keyboard sends the code to the tester if it can be read the protocol will display on the upper right Press to clear the display while the tester is receiving command information 3 3 17 Time setting Press to enter th...

Page 36: ...uage Select your desired language English Chinese etc Brightness Set the brightness of OSD menu and background 0 7 PTZ address search Select off on to add or remove the PTZ address search function Restore default data Restore the device to factory defaults F1 user defined shortcut key You can set the function as you like press to select press to save The default F1 key is the PTZ controller F2 use...

Page 37: ...the tester b Do not apply the output power of the ST HDoC to the input port as this can damage the tester c If a camera that draws more than 1A of power is connected to the output port of the ST HDoC it will enter self protection mode Under this condition disconnect the output power of the meter to the camera and use an external compatible power supply to power the camera d For extended use of the...

Page 38: ...ed on the top of the unit Turn on the tester press for several seconds and the LED lamp will turn on press again to turn off the lamp 4 Specifications 4 1 General Specifications Model ST HDoC ST HDoC MM Video Test Signal mode NTSC PAL Auto adaptive Display 3 5 inch HVGA TFT LCD 480 RGB x 320 resolution LCD adjustment Brightness Contrast Saturation adjustable Video IN OUT 1 channel BNC Input 1 chan...

Page 39: ...io Input Test Audio input test 1 channel audio signal input support audio recording RS485 data analysis Data Monitor Captures and analyzes the command data from a controlling device CVI Test CVI video signal test 1 channel CVI input BNC interface supports 720p 25 30 50 60fps 1080p 25 30fps coxial PTZ controller UTC control TVI Test TVI video signal test 1 channel TVI input BNC interface supports 7...

Page 40: ...lative power value Continuity testing Built in buzzer will sound if resistance is lower than 50 Ω Testing speed 3 samples per second Data range 6600 6600 POWER Power Adapter 5V DC 1 5A Mini USB interface Battery Built in 3 7V Lithium polymer battery 3000mAh Rechargeable After charging 3 4 hour 11 hour average work time Low Consumption Energy saving battery capacity indicator Parameter Operation se...

Page 41: ...00V 1mV 66 00V 10mV 660 0V 100mV AC Voltage Range Accuracy Resolution 660 0mV Manual range 1 5 6 0 1mV 6 600V 0 8 6 1mV 66 00V 10mV 660 0V 100mV DC Current Range Accuracy Resolution 6 600mA 0 5 3 1uA 66 00mA 10uA 660 0mA 100uA 10 00A 1 5 10mA AC Current Range Accuracy Resolution 6 600mA 0 5 3 1uA 66 00mA 10uA 660 0mA 100uA ...

Page 42: ...6 600KΩ 0 8 2 1Ω 66 00KΩ 10Ω 660 0KΩ 100Ω 6 600MΩ 1KΩ 66MΩ 1 2 5 10KΩ Continuity Range Resolution Function 660 0Ω 0 1Ω The measurement value less 30Ω 3Ω the tester will sound Diode Range Resolution Function 2 0V 1mV Schottky diode 0 15 0 25V rectifier diode 0 6 1 0V triode PN junction 0 5 0 8V ...

Page 43: ...F 660 0nF 100pF 6 600μF 1nF 66 00μF 10nF 660 0μF 5 8 100nF 6 600mF 1μF 66 00mF 10μF The data above is only for reference and any change of them will not be informed in advance For more detailed technical inquiries or assistance with using the meter please contact our support line at 1 800 688 9282 ...

Page 44: ... shipping to the Company will be paid by Original Purchaser and all risk for the hardware shall remain with the Original Purchaser until such time as Company takes receipt of the hardware Upon receipt the Company will promptly repair or replace the defective unit and then return said unit to Original Purchaser shipping prepaid The Company may use reconditioned or like new parts or units at its sol...

Page 45: ...ion even if the Company or its agent has been advised of the possibility of such damages or for any claim brought against your by another party Jurisdictions vary with regard to the enforceability of provisions excluding or limiting liability for incidental or consequential damages You should check the laws of your local jurisdiction to find out whether the above exclusion applies to you This warr...