ENFORCER Voice Dialer 

12

 

SECO-LARM U.S.A., Inc. 

 

 

 

Note:

 Should the user have difficulty activating functions remotely by telephone, there may 

be too much ambient noise interference. Try pressing the code key again, or move to a 
quieter location as ambient noise above 68dB may affect the auto dialer’s ability to detect 
the tone signal. 

3.

 

FUNCTION EXPLANATIONS 

LISTEN IN – Pressing [1 #] allows a user to hear sound in the room for 50 seconds. A “beep” 
will sound at 30 seconds to remind the user that the listen in time will soon end. Pressing [1 #] 
again will reset the 50-second period, and entering any other key code will end monitoring and 
perform the function. If there is no other key press, the call will disconnect at the end of the 50 
seconds.  

BROADCAST – Pressing [2 #] allows a user to speak to the person in the room for 50 
seconds. A ‘beep’ will sound at 30 seconds to remind the user that the time will soon end. 
Pressing [2 #] again will reset the 50-second period and entering any other key code (such as 
[1 #], Room Monitor) will end broadcasting and perform the other related function. If there is no 
other key press, the call will disconnect at the end of the 50 seconds. 

 

Note:

 Alternating between “Listen In” and “Broadcast” may be useful for a “conversation” 

with the room occupant, but a user cannot speak and listen at the same time. 

END CALL - Pressing [3 #] will end the call.  

ARM SYSTEM – Pressing [5 #] during a user callback will arm the system, confirming with 
three short “beeps,” and automatically hang up. If there are 5 rapid “beeps” after three short 
“beeps,” it means a door/window is not closed. The dialer will then give 5 seconds to disarm 
the system. 

DISARM SYSTEM – Pressing [6 #] will disarm the system and automatically hang up. 

Note:

 If the user enters an incorrect password or key code, the voice dialer will sound 5 

“beeps” and automatically hang up. 

Operating the Voice Dialer, continued: 

Remote Control by Telephone – Remote Control by User Call-In (Call Back), continued:

 

 

C.

 

Press one of the following function codes to control the system remotely:  

Function 

Press key code 

Listen in 

1 # 

Broadcast  

2 # 

Arm system 

5 # 

Disarm system 

6 # 

The user should hear a “beep” in response. If not, enter the function code again. 

ENFORCER Voice Dialer  

SECO-LARM U.S.A., Inc. 

5

 

 

 

Installing the Voice Dialer, continued:  

1.

 

Select a location for the dialer near a standard electrical outlet (if user-supplied 12VDC 
adapter is to be used), a telephone wall jack, and the alarm control panel, but out of sight. The 
dialer should not be exposed to direct sunlight or rain, and must not be mounted near heat 
sources such as radiators, heating ducts, or stoves. 

2.

 

For wall-mount, use the wall mounting template to 
drill holes and attach 3 screws into the wall at the 
desired location. For convenience, 5~6ft (1.5~2m) 
above the floor is recommended (Fig. 1). 

3.

 

Remove the cable cover and battery cover from 
the back of the voice dialer (Fig. 2).  

4.

 

Install a 9VDC backup battery (not included). 
Reattach the battery cover. 

5.

 

Connect the dialer to up to three detectors or 
groups of detectors in series using the connection 
terminals as shown in the wiring diagram (see pg. 
3). The dialer can also be connected to three 
separate alarm control panel outputs of a separate 
alarm system. When Trigger 3 is used, the jumper 
connection to ground must be removed. 

6.

 

Power: 

a.

 

If the dialer is to be powered from the alarm 
control panel, connect the alarm power outputs 
to the DC Plug-to-terminal block (included) and 
plug into the dialer’s DC power jack (see pg. 3).  

b.

 

If using a 12VDC adapter (not included), plug 
the adapter into the dialer’s DC power jack. 

7.

 

Connect one end of the included telephone cable to 
an existing Touch-Tone line wall socket, and the 
other end to the dialer’s “LINE” jack. The wall socket 
line must be connected to the dialer’s “LINE” jack for  
proper operation. Optionally, connect an extension telephone using the telephone’s cable (not 
included) to the “TEL” jack (Fig. 3). Reattach the cable cover.  

8.

 

If an external alarm is desired, connect according to the wiring diagram (see pg. 3). 

9.

 

For wall installation, place the unit over the heads of the screws installed in step 2 (Fig. 1) and 
slide down. Check that the unit is firmly attached and tighten or loosen the screws as needed. 

10.

 

Once all connections are made, the dialer is ready to be programmed.  

Fig. 3 

Fig. 1 

5~6ft 

(1.5~2m) 

9VDC Battery 
(not included) 

Fig. 2 

Cable 
Cover 

Battery 

Cover 

Summary of Contents for Enforcer E-921CPQ

Page 1: ...ed to monitoring and recording audio and video signals SECO LARM will not be held responsible for the use of this product in violation of any current laws or statutes NOTE While the system can provide valuable protection to home and property when properly installed it cannot guarantee complete protection against intrusion SECO LARM is not responsible for any losses or damage which may occur during...

Page 2: ...Planner 14 FCC Part 68 14 Summary Programming Operation Chart 15 Also Available from SECO LARM 15 Troubleshooting 16 ENFORCER Voice Dialer SECO LARM U S A Inc 15 Summary Programming Operation Chart 1 Setting Changing PIN Number see pg 6 Current PIN PROG ARM DISARM New PIN ARM DISARM PROG x9 2 Setting Emergency Telephone Numbers see pgs 6 7 PIN PROG x2 ARM DISARM DOWN or UP Enter Phone ARM DISARM P...

Page 3: ...ould affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service If trouble is experienced with this equipment US 7M7TE02BE921CPQ for repair or warranty information please contact SmartRG Inc If the equipment is causing harm to the telephone network the telephone company m...

Page 4: ... chime will sound and the word HOME will appear on the LCD screen 2 After 60 seconds another chime indicates that the voice dialer is now in the Home mode 3 When a sensor is activated the voice dialer will chime twice 4 If the panic button is pressed the voice dialer will sound a 30 second alarm and start the dialing sequence to the programmed emergency numbers To deactivate the Home mode simply p...

Page 5: ...m system 5 Disarm system 6 The user should hear a beep in response If not enter the function code again ENFORCER Voice Dialer SECO LARM U S A Inc 5 Installing the Voice Dialer continued 1 Select a location for the dialer near a standard electrical outlet if user supplied 12VDC adapter is to be used a telephone wall jack and the alarm control panel but out of sight The dialer should not be exposed ...

Page 6: ... and holding for two seconds the DOWN or UP buttons respectively The sign shows as and the sign shows as on the LCD screen ENFORCER Voice Dialer SECO LARM U S A Inc 11 2 To disarm the system enter the PIN number and press the ARM DISARM button The dialer will sound a long beep and the word ARM will disappear from the LCD screen Panic Button Use 1 When the PANIC button is pressed the siren will sou...

Page 7: ...nnected only to the TEL jack of the dialer ENFORCER Voice Dialer SECO LARM U S A Inc 7 Deleting a Stored Phone Number 1 Enter the PIN number and press the PROG button twice or until MEMORY flashes on the LCD screen 2 Press the ARM DISARM button to accept 3 Press the DOWN or UP button to select the number you wish to delete 4 Press the DEL PAUSE button to delete the number 5 Press the DOWN or UP bu...

Page 8: ...programming icons disappear to exit the setup mode ENFORCER Voice Dialer SECO LARM U S A Inc 9 Programming the Voice Dialer continued Setting the Entry Delay Time This allows the user to set the length of time before the alarm will sound to allow time to disable the alarm after normal entry The factory default is 20 seconds but can be user programmed for 0 5 10 15 or 20 seconds 1 Enter the PIN num...

Reviews: