background image

ENFORCER Voice Dialer 

14

 

SECO-LARM U.S.A., Inc. 

 

 

 

Program Planner: 

FCC Part 68:  

Use these charts during setup to record phone numbers and sensor locations for future reference. 
It is recommended that you use a pencil during setup and redo it in ink afterwards. The user 
should keep in a safe, easily accessible location and a copy should be retained by the installer. 

Program: Numbers 

Date: 

NUMBER 

PRIORITY 

TELEPHONE NUMBER

 

(include area code and dialer prefix as needed, add PBX 

pause and extension if applicable, see p. 6-7)

 

NAME OF PARTY TO BE REACHED

 

 

 

 

 

 

 

 

 

 

 

 

Installation: Triggers 

Date: 

TRIGGER 

GENERAL DESCRIPTION 

SENSOR LOCATIONS 

 

 

 

 

 

 

 

This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the bottom of the 
device  of  this  equipment  is  a  label  that  contains,  among  other  information,  a  product  identifier  in  the  format 
US:7M7TE02BE921CPQ and REN:0.11B for this equipment.  
This equipment uses the following USOC jacks: RJ-11/RJ45/USB/Power Jacks!  
A  plug  and  jack  used  to  connect  this  equipment  to  the  premises  wiring  and  telephone  network  must  comply  with  the 
applicable FCC Part 68 rules and requirements adopted by the ACTA. A compliant telephone cord and modular plug is 
provided  with  this  product.  It  is  designed  to  be  connected  to  a  compatible  modular  jack  that  is  also  compliant.  See 
installation instructions for details.  

REN (RINGER EQUIVALENT NUMBERS) STATEMENT  

Notice: The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum 
number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any 
combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices 
does not exceed 5.  
If this equipment US: 7M7TE02BE921CPQ causes harm to the telephone network, the telephone company will notify you in 
advance  that  temporary  discontinuance  of  service  may  be  required.  But  if  advance  notice  isn't  practical,  the  telephone 
company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC 
if you believe it is necessary.  
The  telephone  company  may  make  changes  in  its  facilities,  equipment,  operations  or  procedures  that  could  affect  the 
operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make 
necessary modifications to maintain uninterrupted service.  
If trouble is experienced with this equipment US: 7M7TE02BE921CPQ, for repair or warranty information, please contact 
SmartRG, Inc. If the equipment is causing harm to the telephone network, the telephone company may request that you 
disconnect the equipment until the problem is resolved.  
Connection  to  party  line  service  is  subject  to  state  tariffs.  Contact  the  state  public  utility  commission,  public  service 
commission or corporation commission for information.  
If  your  home  has  specially  wired  alarm  equipment  connected  to  the  telephone  line,  ensure  the  installation  of  this  US: 
7M7TE02BE921CPQ  does  not  disable  your  alarm  equipment.  If  you  have  questions  about  what  will  disable  alarm 
equipment, consult your telephone company or a qualified installer.  

ENFORCER Voice Dialer  

SECO-LARM U.S.A., Inc. 

3

 

 

Back Connection Area (Cover Removed) 

LINE     TEL 

Telephone Wall Jack 

Buzzer (–) O/P 

Buzzer (+) O/P 

or 

Telephone Extension 

External Alarm/Siren 

CA- 161T 
DC Plug-to-Terminal 
Block  

Power Adapter  
(Not Included) 

SM-206Q* 

E-964-D390Q* 

NO/NC Trigger in 1 
NO/NC Trigger in 2 

N.C. Trigger in 3 

Trigger ground 

SM-200Q* 

Note:

 For proper operation, the telephone extension 

line and wall jack line must not be reversed. 

Operating voltage 

9~12 VDC 

Current draw  
Max. (at 12VDC) 

Standby 

5mA 

Dialing 

20mA 

Alarm On 

150mA 

Relay On 

50mA 

Speaker On 

250mA 

Total 

480mA 

Emergency voice message length (user recorded) 

Up to 20s 

Programmable emergency phone numbers 

Maximum digits per telephone number 

32 

Backup battery type/life (not included) 

9VDC/≈20h 

Alarm sound level at 12" (30cm) 

≥105dB 

Trigger inputs 

Triggers 1 and 2 

NO/NC Trigger (auto-detected) 

Trigger 3 

N.C. Trigger 

Trigger input timer 

≥500ms 

Auxiliary output current (max) 

125mA 

Operating temperature 

32°~104°F (0°~40°C) 

Storage temperature 

-4°~140°F (-20°~60°C) 

Weight 

11.15-oz (316g) 

Dimensions 

6

11

/

16

"x4

11

/

16

"x1

1

/

2

" (170x119x38 mm) 

 

1x  Voice dialer unit 

1x  Telephone cable  

1x  Remote control instruction card 

1x  DC Plug-to-terminal block 

3x   Plastic wall anchors 

3x   Wall mount screws 

1x  Wall mounting template 

1x  User manual 

Parts List:  

* E-964-D390Q Photobeam Detectors, SM-200Q Magnetic Sensors, and SM-206Q Concealed Magnetic Sensors shown as 

examples only: For other sensors and products available from SECO-LARM, please visit our website at www.seco-larm.com. 

Specifications:  

Wiring Diagram:  

Summary of Contents for Enforcer E-921CPQ

Page 1: ...ed to monitoring and recording audio and video signals SECO LARM will not be held responsible for the use of this product in violation of any current laws or statutes NOTE While the system can provide valuable protection to home and property when properly installed it cannot guarantee complete protection against intrusion SECO LARM is not responsible for any losses or damage which may occur during...

Page 2: ...Planner 14 FCC Part 68 14 Summary Programming Operation Chart 15 Also Available from SECO LARM 15 Troubleshooting 16 ENFORCER Voice Dialer SECO LARM U S A Inc 15 Summary Programming Operation Chart 1 Setting Changing PIN Number see pg 6 Current PIN PROG ARM DISARM New PIN ARM DISARM PROG x9 2 Setting Emergency Telephone Numbers see pgs 6 7 PIN PROG x2 ARM DISARM DOWN or UP Enter Phone ARM DISARM P...

Page 3: ...ould affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service If trouble is experienced with this equipment US 7M7TE02BE921CPQ for repair or warranty information please contact SmartRG Inc If the equipment is causing harm to the telephone network the telephone company m...

Page 4: ... chime will sound and the word HOME will appear on the LCD screen 2 After 60 seconds another chime indicates that the voice dialer is now in the Home mode 3 When a sensor is activated the voice dialer will chime twice 4 If the panic button is pressed the voice dialer will sound a 30 second alarm and start the dialing sequence to the programmed emergency numbers To deactivate the Home mode simply p...

Page 5: ...m system 5 Disarm system 6 The user should hear a beep in response If not enter the function code again ENFORCER Voice Dialer SECO LARM U S A Inc 5 Installing the Voice Dialer continued 1 Select a location for the dialer near a standard electrical outlet if user supplied 12VDC adapter is to be used a telephone wall jack and the alarm control panel but out of sight The dialer should not be exposed ...

Page 6: ... and holding for two seconds the DOWN or UP buttons respectively The sign shows as and the sign shows as on the LCD screen ENFORCER Voice Dialer SECO LARM U S A Inc 11 2 To disarm the system enter the PIN number and press the ARM DISARM button The dialer will sound a long beep and the word ARM will disappear from the LCD screen Panic Button Use 1 When the PANIC button is pressed the siren will sou...

Page 7: ...nnected only to the TEL jack of the dialer ENFORCER Voice Dialer SECO LARM U S A Inc 7 Deleting a Stored Phone Number 1 Enter the PIN number and press the PROG button twice or until MEMORY flashes on the LCD screen 2 Press the ARM DISARM button to accept 3 Press the DOWN or UP button to select the number you wish to delete 4 Press the DEL PAUSE button to delete the number 5 Press the DOWN or UP bu...

Page 8: ...programming icons disappear to exit the setup mode ENFORCER Voice Dialer SECO LARM U S A Inc 9 Programming the Voice Dialer continued Setting the Entry Delay Time This allows the user to set the length of time before the alarm will sound to allow time to disable the alarm after normal entry The factory default is 20 seconds but can be user programmed for 0 5 10 15 or 20 seconds 1 Enter the PIN num...