7
Terminal Connections
Terminal
Description
POWER
Earth
Connect to mains earth via plug pack
Note:
remove solder tinning on earth wire, if provided, before connecting.
16 vac
AC input 16v AC plug pack
( As supplied with unit only )
16 vac
AC input 16v AC plug pack
( As supplied with unit only )
BATT +
12v DC battery input Positive
BATT -
12v DC battery input Negative
FAULT RELAY
NC
normally closed contact
C
common contact
N0
normally open contact
Warning: fault relay is at TNV-3 and is rated 0.5 A at 125 vac
ZONE INPUTS
(24hr Multibreak)
10k E.O.L. ( MUST BE INSTALLED
)
C
Common for Zones Inputs ( negative float )
4
10k end of line resistor required to common
3
10k end of line resistor required to common
C
Common for Zone Inputs ( negative float )
2
10k end of line resistor required to common
1
10k end of line resistor required to common
PSTN
To Mode 3 T-Socket ( to panel and phone line )
CON 1
Used for programming via telephone handset and for audio across GSM
Wiring and Terminations
1.3