18
SMS Commands
The SED 62/64 Zone Inputs can be armed or disarmed by sending the
following SMS Text Message. This command will arm/disarm all Zone Inputs.
Zone Arm and Disarm feature
Example (for Relay 5)
out5on
= Turns Relay 5 on
(indefinitely)
out5off
= Turns Relay 5 off
(indefinitely)
out5on2
= Turns Relay 5 on for 2 seconds
(if relay is off)
out5off2
= Turns relay 5 off for 30 seconds
(if relay is on)
Relay Control
The SED 62/64 Zone Inputs can be programmed with individual text labels
for SMS reporting.
Zone Inputs Individual Text Labels
Arm / Disarm Commands
?ON
= Arms all 4 zones
(must be in capitals)
?OFF
= Disarms all 4 zones (must be in capitals)
Important:
It is advisable to program functions 16,17 & 18 to Option 1, and
program the mobile numbers into function 12, 13 & 14 if necessary
.
The following SMS commands control additional features of the SED 62/64
Example:
ina1front door
will program Zone 1 alarm with “front door alarm” (MAX 10 CHAR)
Note:
Relays 1 - 4 are via an expander board, which must be enabled in programming (see
function 25). Relay 5 is onboard as standard and Relay 0 can be enabled if the fault relay is
not required (see function 24).
Text Message Format
in
<State><Input><Text>
To Clear: send without <Text>
Parameter Description:
<State> = “a” for alarm and “r” for restore
<Input> = Zone Input Number
<Text> = Max 10 Characters (including
spaces)
Text Message Format
out
<Relay>
on
{Timer
}
out
<Relay>
off
{Timer
}
Parameter Description:
<Relay> = Relay Number
{Timer} = Optional timer value
in Hours [h] minutes [m] and
seconds
To control the SED 62/64 Output Relays, send an SMS message as follows:
2.9
NOTE
:
SMS commands must be as shown. (MUST BE IN CAPITALS)
Summary of Contents for SED-64