SecEng SED-64 Installation & User Manual Download Page 3

3

Section 1 - BASIC SETUP

1.1

Installation Overview Diagram option systems

1.1A

SED-64 system board guide 

1.2

SIM Card Installation

1.3

Wiring and Terminations 

1.4 

Indication Lights

1.5

Operating Modes & Programming

Section 2 - INTELLIGENT SETUP

2.1

Manual Programming Mode

2.2

SMS Programming Mode

2.3

Programming Functions Summary

2.4

Program functions 1-6

2.5

Program functions 7-11

2.6

Program functions 12-16

2.7

Program functions 17-25

2.8

SMS reports

2.9

SMS commands

2.10

Control Room report codes

2.11

Reserved

Section 3 - GPRS SET UP

3.1

Enabling GPRS 

3.2

Operational mode in GPRS

Section 4 - TESTING AND HELP

4.1

SED-64 Testing and Commissioning

4.2

Fault Guide 

4.3

GPRS Testing 

4.3

Technical Support

Section 5 

– 3G BAND SELECTION

5.1

3G band selection guide

Section 6 

– SED-64 BOARD OPTIONS 

6.1

SED-64 Board option systems dual serial

6.2

SED-64 Board options systems single serial

6.3

SED-64 Board option systems 4 way I / O

6.4

SED-64 Board option systems (Mode 3 board)

TABLE OF CONTENTS

Summary of Contents for SED-64

Page 1: ...If it can operate on 3G or GSM This product is GPRS enabled via SUREPOLL WIRELESS WARNING THIS SECURITY DEVICE MUST BE INSTALLED BY A QUALIFIED AUTHORIZED PERSON PLEASE READ THIS MANUAL FULLY BEFORE I...

Page 2: ...12 month Back to Base Warranty from the date of purchase and proof of purchase should be supplied The warranty does not cover damage that has resulted in the improper installation or use of the produc...

Page 3: ...functions 12 16 2 7 Program functions 17 25 2 8 SMS reports 2 9 SMS commands 2 10 Control Room report codes 2 11 Reserved Section 3 GPRS SET UP 3 1 Enabling GPRS 3 2 Operational mode in GPRS Section 4...

Page 4: ...AC light should be on 3 Enable option 48 to a 1 disable dynamic battery test Earth 16vac Batt AC 12v dc in To zone on Alarm Panel STD DTMF PHONE FOR PROGRAMMING OPTIONAL Expander Board Port optional...

Page 5: ...4 way I O Panel Phone LD1 LD2 SED 64 mode3 Single Relay Board l NC C NO led 1 2 RS232 NC C NO led Dual serial Interface Single Relay Board l Sed 64 4way I O Part Sed 64 DSI Port 1 used to program Sed...

Page 6: ...card To disable the PIN go to the mobile phone security menu and select PIN OFF Unlocked SIMM CARD 1 2 If the phone requests you to enter a pin number then the SIM card is PIN LOCKED NOTE The SIM car...

Page 7: ...contact C common contact N0 normally open contact Warning fault relay is at TNV 3 and is rated 0 5 A at 125 vac ZONE INPUTS 24hr Multibreak 10k E O L MUST BE INSTALLED C Common for Zones Inputs negat...

Page 8: ...ed Indicates the digit 8 9 OH GSM Transmitting Indicates the digit 9 0 PWR Power On Indicates the digit 0 13 Fault Relay Fault Relay 14 Line Fault Telephone line not detected 15 AC AC OK If LED 6 FLT...

Page 9: ...GSM fault relay into a 24Hr zone on the customers alarm panel INTELLIGENT BACK UP SYSTEM WE RECOMMENDED THAT THE INTELLIGENT MODE BE USED IN MOST CASES 1 2 3 There are 2 available methods to program...

Page 10: ...from any mobile phone Simply write a text message in the format of Function No Option No and then send it to the SIM card mobile phone number in the SED 64 Manual Programming Mode This now has progra...

Page 11: ...ing codes 10 Ademco event codes of on board GSM dialer 0 11 Software Version Read only n a SMS set up and control 12 Mobile phone 1 for SMS alarms nil 13 Mobile phone 2 for SMS alarms nil 14 Mobile ph...

Page 12: ...Internal CID RX kiss off time adj 1 9 seconds 2 33 Digital volume adj for RX level 1 9 5 34 Digital volume adj for TX level 1 9 5 35 NA nil 36 NA nil 37 NA nil 38 Input 1 4 bounce delay in 20ms block...

Page 13: ...hange the time between the SED 62 64 test call reports sector 253 The time is in Hour intervals Options From 0 to 168 Hours Example 0424 sets a test call every 24 hours 0 No test call reports 24 Test...

Page 14: ...tivations on a zone input Sets the starting number for the SED 62 64 onboard dialler reporting codes In most cases reporting codes 250 and above are OK to use as the alarm panel does not need this man...

Page 15: ...AC Fail Low Batt GSM Test and Fail to Communicate Option 1 Sends All System Messages to Mobiles Option 2 Send all system Messages except GSM Test Options 0 Disable SMS Messages 1 Enable Option 1 2 Ena...

Page 16: ...0 see Section 2 9 for SMS output control Options 0 Option 0 1 Option 1 2 Option 2 Example 242 Relay controlled by SMS Enables the I O expander board option Only enable this if an I O expander board ha...

Page 17: ...GSM Dialer test i1 input 1 TO timed out BF battery fail LB Low battery i2 input 2 PB program via button Gf GSM fail PF AC Power fail i3 input 3 PS program via sms Ipr fail ip address SF GSM signal fa...

Page 18: ...nd program the mobile numbers into function 12 13 14 if necessary The following SMS commands control additional features of the SED 62 64 Example ina1front door will program Zone 1 alarm with front do...

Page 19: ...ail 140 Sector 252 140 Sector 452 351 Sector 000 GSM test 140 Sector 253 140 Sector 453 602 Sector 000 Zone Input 1 140 Sector 254 140 Sector 454 140 Sector 001 Zone Input 2 140 Sector 255 140 Sector...

Page 20: ...enabled You can now operate the SED 64 in either mode 1 or mode 2 for GPRS MODE 1 The SED 64 will allow the alarm panel to dial out on the phone line as normal but will poll the SED 64 every 90 second...

Page 21: ...eck Section 3 2 to diagnose the problem 5 Once testing is complete plug the telephone line back in to the T socket The line fail LED should go out and after about 1 minute the fault relay will de acti...

Page 22: ...client code If the unit has not been programmed before the client code should be 0000 If no LEDs illuminate then the SED 62 64 may have a Master Code Function 19 You can now try defaulting the SED 64...

Page 23: ...ms Next with the butt still plugged into CON1 unplug the t socket from the phone line wait for line fail LED to activate then activate an input on the Alarm Panel Listen in on the call while the Alarm...

Page 24: ...Id receiver via GSM and not via GPRS GPRS Testing MODE 2 BASIC GPRS COMMS 1 If the OH light is flashing every 3 seconds then rapidly every 40 seconds you are Polling on GPRS Call Suretek on 1300 65 44...

Page 25: ...ng the band selection for the 3G network normally should not be touched as is automatic 5 1 Examples 1 GSM850 2 EGSM 900 4 GSM1800 6 EGSM GSM1800 8 GSM1900 9 GSM850 GSM1900 10 EGSM900 GSM1900 15 QUADB...

Page 26: ...or on the SED 64 marked SERIAL PROGAMMING Connect any laptop or PC using a straight thru serial connection onto Serial 1 On the SED 64 this allows for programming and set up for the SED 64 Connect usi...

Page 27: ...fit board as shown NC C NO FAULT Con 1 Earth 16vac Batt Volts TEST PROG PSTN C 1 2 C 3 4 ZONE INPUTS LineFailLED AC sim card holder SED 64 STATUS WAKE serial prog volts 5 4 3 2 1 0 9 8 7 6 FLT OH PWR...

Page 28: ...AKE serial prog volts 5 4 3 2 1 0 9 8 7 6 FLT OH PWR ZONEFAULT LOWBATT SIGNAL STATUS 1 2 RS232 SED 64 4 way I O Inputs x 4 Outputs x 4 Part SED 64 4 way I O 10 WAY RIBBON LEAD INSTALLATION PROCESS 1 P...

Page 29: ...LD1 LD2 SED 64 mode3 Here Mode 3 relay board is used for GPRS systems whereby you need the clients phone line returned to the customer and the panel thus working GPRS full time Install as shown Con 1...

Page 30: ......

Reviews: