alarm line function can be tested then.

For standalone access control with doorbell button, LED4 will be on when the doorbell key is pressed and be off when

releasing the key.

For information of test for Wiegand output function of D0 and D1 and the card reader mode of the standalone access

control, Please refer to operations of card reading test in following.

3. Operations of card reading test

3.1 wiring

According to the following wiring diagram, connect the outgoing wire of the card reader into the quick connection base of

the access control special test tool according to the color and function, turn the switch K1 to the "card reader", and turn

the "power switch" SW7 from "off" to "on". After the machine enters the standby state, the following tests can be started.

sGuard Wiring 2

3.2 Card Reader Operating Current

If no operation within 3 minutes after power-on, the first 4 digits of the nixie tube display the working current of the

external card reader, then end display and enter into sleep mode. For example, 0.035 means 0.035A, or 35mA. There is no

current value displayed when displaying Wiegand output data.

The device will cut off the power supply When the current of the external access control card reader exceeds 200mA. The

power supply will be recovered automatically 5 seconds later after the over current is eliminated.

3.3 Function Test

3.3.1 Initialize working mode

Mode 1: Wiegand 4Bit button code, Wiegnad 8Bit button code, Wiegand26-37Bit Card No with even/odd check digits.