1. Technical parameters and functional features
power supply requirements:
DC12V
≥
500mA
Static working current:
≤
100mA
Working current of external access control:
≤
200mA (over current and short circuit protection)
Accuracy of working current of standalone access control or card reader:
±
1mA
Keypad:
touch panel
Function 1:
Test the functions of the standalone access control including exit button, door magnetic switch, unlock relay
No and NC, Alarm, Door bell button, etc
Function 2:
Set the type of card reader, key and output format of card reader
Function 3: T
est the functions of D0, D1, led and BZ wires of the reader
Function 4
:
Display the reader's output format, 4 bit, 8 bit key data, 26-37 bit card number data
Function 5
:
Display 10 bit format card number. Switch 10-bit to 8-bit format card number