Installation & User Manual 

V2.022

Contents

Other Access Control Products

standalone products

Also available is a range of fully functional standalone door controls for less
complex door management. This attractive design, with modern aesthetics, will

complement and building.

 - 1 and 2 Door Digital Keypads

 - Proximity Switch
 - Biometric Switch

Features:

- (35 - 1000) users
- Access control

- Door monitoring
- Manager user

- fire and intruder alarm interface
- Backlighting

- Tamper resistant
- 5 amp relays

- Indoor or outdoor use
- Robust polycarbonate housing with stainless steel keys
- Mounts onto a standard electrical back box

Wi-Bio

2

Operation Instructions

3

Installation Diagrams

4

Wiring Diagrams

10

 8

Enrolling Door Controls

Finger Placement

Simple Secure Access

www.argusaccess.com

Summary of Contents for Wi-Bio

Page 1: ...Door Digital Keypads Proximity Switch Biometric Switch Features 35 1000 users Access control Door monitoring Manager user fire and intruder alarm interface Backlighting Tamper resistant 5 amp relays Indoor or outdoor use Robust polycarbonate housing with stainless steel keys Mounts onto a standard electrical back box Wi Bio 2 Operation Instructions 3 Installation Diagrams 4 Wiring Diagrams 10 8 En...

Page 2: ...amming Code 55 Code Present Finger to Confirm Note If programming code is lost Remove the Tamper Wing and hold down the 5 key during power up and enter the default programming code 6666 Note The Door Control can only be defaulted if it is not part of a network i e If the Door Control has not been assigned an address To release Security Caps push a screwdriver into slots on the side and pull forwar...

Page 3: ...Used ONLY for Wired 485 Network Connections 4 Wiring Diagrams Follow Relay Lock Door 5 Wiring Diagrams Door 12V Varistor OP2 OP1 IP1 IP2 IP3 12V Sounder Follow Relay Common OV from the Fire Alarm Panel and the OV from the Door Control to avoid any ground loop issues When the fire alarm is activated 0V removed from IP3 the door will be opened Always connect a varistor between the lock terminals 0V ...

Page 4: ... COM NO 0V 12V A B 0V Note Used ONLY for Wired 485 Network Connections Door 12V Varistor OP2 OP1 IP1 IP2 IP3 12V Sounder Always connect a varistor between the lock terminals Wiring Diagrams with Alarm Panel Connections B A NC COM NO 0V 12V A B 0V Note Used ONLY for Wired 485 Network Connections Arm Alarm Input Arm Output N O Common OV from the Intruder Alarm Panel and the OV from the Door Control ...

Page 5: ...ssigned Click Secure Network Assigning a Door Address on a Wired 485 Network Step Description 1 Right Click on the Controller Icon select Manually Assign Addresses Follow Step 2 above to complete the process Enrolling Door Controls Adding Door Controls Step Description 1 Click the Doors Icon on the left hand toolbar on the PC application 2 Click Add New Door 3 The Door is added to the Controller 4...

Page 6: ...Correct Finger Placement 10 Finger Placement Incorrect Finger Placement 11 Finger Placement ...