Do not use machine as a step.
If vacuum is used on plush carpet or carpet with thick padding, do not leave machine standing in one place with machine turned
on.
Keep hair, loose clothing, fingers, and all parts of body away from machine openings and moving parts. Do not place fingers or
other body parts under machine, unless it is unplugged.
Do not place the power head over rug or carpet edges.
The vacuum has a manual reset thermal protector. The protector is reset by switching off the vacuum. The thermal protector
needs some time to cool down after switching off! Check the vacuum for air blockages or mechanical failures before switching on.
Store the vacuum in a dry place at room temperature. When the vacuum is not in use, you should wrap the cord on the cable
hooks.
Any other servicing should be performed by an authorized service representative.
Special Product Features
Your SEBO essential G series vacuum cleaner is the most technically advanced upright vacuum cleaner
in the world. Along with its excellent filtration system (99.9% to 0.3 microns), the machine has warning
systems and automatic shut-off capabilities that are designed to alert the user to machine problems
that, if ignored, will damage the machine or diminish performance. Some of your SEBO essential�s
most unique features are:
1.
S-Class Filtration
Certified by leading Allergy foundations in Europe, the essential G-Series vacuum
provides the user with S-Class filtration of 99.9% of particles to 0.3 microns.
This is accomplished by the SEBO three-step filtration system. First, the three-
layer full-size filter bag (a) collects the vast majority of the debris. Then, the
remainder of the particles are collected by the hospital-grade micro filter (b).
Finally, the micro-exhaust filter (c) cleans the exhaust air that the vacuum
emits. Sebo's unwavering attention to the complete sealing of the machine
ensures no dust or dirt escapes around the micro filters. If the micro filters are
changed regularly (every 10-20 bags), the essential G is perfect for allergy or
asthma sufferers.
2.
Brush Roller Obstruction
Auto Shut-Off. If the brush roller is obstructed, the machine will shut off in 3
seconds and the red �CHECK BRUSH� light located on top of the power head
will flash. The user should turn the switch off, unplug the machine and
immediately remove the obstruction. If the user restarts the machine without
removing the obstruction, the machine will again shut off in 3 seconds and the
�CHECK BRUSH� light will flash.
3.
Brush Roller Deterioration Warning
If the red �CHECK BRUSH� light is illuminated continuously while the head is in
position 1 (after a 10 second delay) it is signaling the user that the brush roller
is too worn and, therefore, should be replaced. The light will remain illuminated
until the worn brush roller is replaced, but the machine will continue to operate
in the meantime.
4.
Stationary Use Warning
When the machine has its handle in the upright-locked position, it is designed to disengage the brush
roller from the floor by raising the height of the power head. If the power head is in position 1 (the
highest setting) but is still engaged in the carpet, the �CHECK BRUSH� light will slowly flash to alert
the user. This can occur on extremely high-nap carpet, such as
loose-pile shag, or on carpets with extraordinarily thick padding
underneath. However, it is typically caused by the user pulling
forward on the machine while using the attachment hose or active
wand. This feature was designed to be an alert to the user to �take
care� while the machine is stationary. An operating machine should
not stand stationary on the floor for inappropriate periods of time.