2 rev. 3.0 13/06/2016
TECHNICAL DATA:
- Power supply : 230 Vac 50-60Hz 8W max.
- Flashing light output : 230 Vac 50Hz
100W Resistive Load max.
50W Inductive Load max.
- Motor output : 230 Vac 50-60Hz 750 W max.
- Services power supply output : 24 Vac 6 W max.
- Safety devices and controls in BT : 24 Vdc
- Operating temperature : -10
÷
55 °C
- Radio receiver : see model
- Op. transmitters : 12-18 Bit or Rolling Code
- Max. TX codes in memory : 120 (CODE or PED CODE)
- Board dimensions : 108x138 mm.
TERMINAL BOARD CONNECTIONS:
CN1 :
1 : Grounding Connection.
2 : Grounding Connection.
CN2 :
1 : 230 Vac line input (Phase).
2 : 230 Vac line input (Neutral)
3 : 230 Vac Flashing light Output (Neutral).
4 : 230 Vac Flashing light Output (Phase).
5 : Opening 230V Motor Output.
6 : Common 230V Motor Output.
7 : Closing 230V Motor Output.
CN3:
1 : Photocell Control and Power Supply ( 24Vac 6W ).
2 : Photocell Control and Power Supply (GND).
3 : Step-by-step control Button Input / Open (NO).
4 : Blocking Device Input (NC) / Button Close (NO).
5 : Common GND input
6 : Safety device input (NC).
7 :
Motor Opening Limit Switch Input (NC).
8 : Common GND input.
9 : Motor Closing Limit Switch Input (NC).
10: Antenna Ground Input.
11: Antenna hot Pole Input.
CN4:
1 : Aux power 24Vdc.
2 : Output 4 Open Collector 100mA Max Load.
3 : Output 3 Open Collector 100mA Max Load.
4 :
Output 2 Open Collector 100mA Max Load.
5 : Output 1 Open Collector 100mA Max Load.
CN5:
1 : Motor Encoder Power 24Vdc.
2 : Motor Encoder Signal Input.
3 : GND Motor Encoder Power Supply.
OPERATING FEATURES:
Step-by-step operation:
By using either the radio-control ( CODE led on ) or the low
voltage buttons to activate the gate, you obtain the following
action:
the first impulse activates the opening mechanism until the
motor time expires or the opening limit switch is reached, the
second impulse closes the gate. If an impulse is sent before
the motor time expires or one of the two end runs are reached,
the control unit will stop both opening and closing movements.
An additional control re-starts motion in the opposite direction.
Automatic closing :
The control unit closes the gate automatically without sending
additional commands.
The choice of this operating mode is described in the
instructions for setting the delay period.
Pedestrian Passage:
The control unit allows, using either the radio-control (P.
CODE led on) or the Pedestrian button, the Motor to run
for a programmable amount of time.
Blocking Device Input :
The control unit allows the blocking button connection (NC).
Tripping during any operating phase of the control unit causes
movement to stop immediately. An additional movement control
will be valid as long as you have disabled the blocking input,
and, in any case, the unit will carry out the opening stage
automatism with pre-flashing for 5 seconds. If the automation is
fully open, in this case, it will carry out the closing phase.
Attention: Jumper this input if not used.
Photocells:
The control unit allows Photocells to be powered and
connected in accordance with directive EN 12453.