                                                                                                 5                                                            rev. 3.0   13/06/2016 

 

LED, and then press the SET key. At this point the CODE LED 
lights up steady and programming is finished.  
Accordingly,  using  either  the  radio-control  or  the  low  voltage 
push  button  panel  to  operate  the  gate,  you  will  obtain  the 
following  function:  the  first  impulse  controls  opening  until  the 
motor time expires, the second impulse controls gate closing. If 
an  impulse  is  sent  before  the  motor  time  expires,  the  control 
unit changes the direction of motion in the opening and closing 
phases.  Repeat  the  procedure  if  you  wish  to  restore  the 
previous configuration. 
 
B) PED. CODE  ( Electronic Brake ) : 
The  control  unit  is  supplied  by  the  manufacturer  with  the 
electronic  brake  function  disabled.  If  you  wish  to  enable  the 
function,  proceed  as  follows:  check  that  Extended  Menu  1  is 
enabled  (T.  MOT.  PED  and  T.  PAUSA  LEDs  start  flashing 
alternately),  use  the  SEL  button  to  move  to  the  flashing  PED 
CODE  LED  then  press  the  SET  key:  at  that  point  the  PED 
CODE LED will light up steady and programming is complete.  
Accordingly, the control unit slows down gate advancement by 
inertia,  when  there  is  a  stop  or  command  to  change  the 
direction of motion. Repeat the procedure if you wish to restore 
the previous configuration.  
 
C) INB. CMD. AP ( Anti-collision Function ) : 
The  control  unit  is  supplied  by  the  manufacturer  with  the  Anti-
collision  (pedestrian)  Function  disabled.  If  you  wish  to  enable 
the  function,  proceed  as  follows:  check  that  Extended  Menu  1 
is  enabled  (T.  MOT.  PED  and  T.  PAUSA  Leds  flash 
simultaneously),  use  the  SEL  button  to  move  to  the  flashing 
INB.  CMD.  AP.  LED    and  then  press  the  SET  button.  At  this 
point  the  INB.  CMD.  AP.  LED  will  light  up  steady  and 
programming  is  complete.  The  control  unit  will  now  operate  in 
Anti-Collision (pedestrian) mode.  
If you wish to enable the Anti-Collision (pedestrian) function for 
the  closing  phase  only,  repeat  the  operation  described  above, 
pressing the SEL key twice (making the IN.CMD.AP. LED flash 
quickly).  Repeat  the  procedure  if  you  wish  to  restore  the 
previous configuration. 

 

D) LAMP/CORT.  ( Deceleration ):  
The  control  unit  of  the  plant,  the  deceleration  function  and 
obstacle  detection  during  deceleration  enabled.  If,  however, 
you  do  not  want  to  have  any  slowdown,  you  can  exclude  it:  in 
this  way  using  automatic  programming  will  no  longer  be 
automatically  activated  during  deceleration,  or  using  the 
Programming  Times  Motor,  will  no  longer  be  given  the 
opportunity  to  plan  the  stages  of  slowing  down.  Once  you 
disable  the  slowdown  phase  will  be  necessary  to  repeat  the 
programming  Automatic  or  manual  Times  Engine.  If  you  want 
to  disable  the  slowdown  proceed  as  follows:  Make  sure  you 
have  enabled  the  Extended  Menu  1  (indicated  by  the  LEDs 
flash alternately T.MOT.PED and Led T. PAUSE), use the SEL 
button  on  the  flashing  of  LED  LAMP  /  CORT.  and  then  press 
the  SET  key:  the  LAMP  /  CORT.  will  shut  down  permanently 
and  programming  is  complete.  If  you  want  to  re-enable  the 
deceleration  phase,  repeat  the  above  operation,  by  pressing 
the SEL button (getting the normal flashing LED LAMP / CORT 
to  enable  the  slow  and  obstacle  detection  during  the 
deceleration phase) when you press two times (getting the fast 
blinking  LED  LAMP  /  CORT  to  enable  the  slowdown  without 
obstacle detection during the deceleration phase). 
 
E) PGM. AUT. ( Follow Me ) : 
It is possible to set the "Follow Me" function on the control unit: 
this  function  can  only  be  programmed  if  a  Pause  Time  has 
already been programmed, and it is used to shorten the Pause 
time  to  5  sec  after  the  photocell  disengages,  i.e.  the  gate 
closes  5  seconds  after  the  user  has  passed  through.  If  you 
wish  to  enable  the  function,  proceed  as  follows:  check  that 
Extended  Menu  1  is  enabled  (T.  MOT.  PED  and  T.  PAUSA 
Leds flash simultaneously), use the SEL button to move to the 
flashing  PGM.  AUT.  LED    and  then  press  the  SET  key:  the 
PGM.  AUT.  LED    will  light  up  steady  and  programming  is 

complete.  Repeat  the  procedure  if  you  wish  to  restore  the 
previous configuration.  
 
F) T. MOT.  ( ENCODER ) : 
The  control  unit  supplied  by  the  manufacturer  can  manage 
Motors  with  a  point  Encoder;  in  the  default  configuration, 
Encoder  point  control  is  disabled.  If  you  wish  to  enable  the 
control,  proceed  as  follows:  check  that  Extended  Menu  1  is 
enabled  (T.  MOT.  PED  and  T.  PAUSA  LEDs  start  flashing 
alternately),  use  the  SEL  button  to  move  to  the  flashing  T. 
MOT.  LED  then  press  the  SET  key:  at  that  point  the  T.  MOT 
LED will light up steady and programming is complete. Repeat 
the procedure if you wish to restore the previous configuration. 

 

EXTENDED MENU 2 

     

The  control  unit  is  supplied  by  the  manufacturer  with  the 
possibility of directly selecting the main menu functions only. 
If you wish to enable the functions described in Extended Menu 
2,  proceed as follows: access Extended Menu 1 (as described 
in the relative paragraph), then press and hold the SET button 
down  again  for  5  seconds,  after  which  amount  of  time  the  T. 
MOT.  PED  and  T.  PAUSA  LEDs  will  start  flashing 
simultaneously.  The  user  then  has  30  seconds  to  select  the 
functions for Extended Menu 2 using the SEL and SET buttons. 
After  another  30  seconds  the  control  unit  will  go  back  to  the 
main menu. 
 

----------------------    EXTENDED MENU 2    ----------------- 

Led Reference Led Off Led On 

A) CODE                   remote PGM = OFF     remote PGM = ON       
B) PED. CODE    Photocell Test = OFF        Photocell Test= ON 
C) IN.CMD.AP.  Sens1 = rev. in CH            Sens1 = brief rev. AP/CH 
D) LAMP/CORT.Sens2 =stop AP/CH         Sens2 = brief rev. AP/CH     
E) PGM. AUT.         PUL=PUL – BL=BL           PUL=AP  -  BL=PED 
F) T.MOT.               PUL=PUL – BL=BL           PUL=AP  -  BL=CH 
G) T. MOT. PED.              Simultaneous ON/OFF flashing                              
H) T. PAUSA                       Simultaneous ON/OFF flashing                   

 

A) CODE ( Remote radio-control programming ) : 
The  control  unit  allows  the  transmission  code  to  be 
programmed,  without  using  the  SEL  button  directly  on  the 
control unit, but remotely. 
The  Radio-control  can  be  remotely  programmed  as  follows: 
continuously  sending  a  previously-memorised  radio-control 
code  for  more  than  10  seconds.  At  this  point  the  control  unit 
switches  to  programming  mode,  as  described  above  for  the 
CODE LED in the main menu. 
The  control  unit  is  factory  supplied  with  the  remote 
transmission  code  programming  function  disabled.  If  you  wish 
to enable the function, proceed as follows: check that Extended 
Menu  2  is  enabled  (T.  MOT.  PED  and  T.  PAUSA  LEDs  flash 
simultaneously),  use  the  SEL  button  to  move  to  the  flashing 
CODE  LED,  then  press  the  SET  key:  at  this  point  the  CODE 
LED will light up steady and programming is complete. Repeat 
the procedure if you wish to restore the previous configuration. 
 
B) CODE PED.  (Photocell Test) : 
The  control  unit  is  factory  supplied  with  Photocell  Test 
programming  disabled.  If  you  wish  to  enable  the  function  (in 
accordance  with  Standard  EN  12453),  proceed  as  follows: 
check  that  Extended  Menu  2  is  enabled  (T.  MOT.  PED  and  T. 
PAUSA  Leds  flash  simultaneously),  use  the  SEL  button  to 
move to the flashing CODE PED.  LED then press the SET key: 
at  this  point  the  CODE  PED.  LED  will  light  up  steady  and 
programming  is  complete.  Accordingly,  the  Safety  Device  test 
will  be  carried  out  before  the  automation  starts  any  type  of 
motion.  Repeat  the  procedure  if  you  wish  to  restore  the 
previous  configuration.  When  the  Safety  Device  inputs are not 
in  use  they  must  be  jumpered  and  the  Photocells  Test 
deactivated. 
 
 

 

Summary of Contents for LRX 2271

Page 1: ... up an isolating device inside the system It is necessary to install an omnipolar switch surge category III It must be positioned to provide protection from accidental closing pursuant to point 5 2 9 of EN 12453 6 For the power supply cables use flexible cables in an insulating sheath in harmonised polychloroprene H05RN F with a minimum conductor section of 1mm2 7 The various electrical components...

Page 2: ... Encoder Signal Input 3 GND Motor Encoder Power Supply OPERATING FEATURES Step by step operation By using either the radio control CODE led on or the low voltage buttons to activate the gate you obtain the following action the first impulse activates the opening mechanism until the motor time expires or the opening limit switch is reached the second impulse closes the gate If an impulse is sent be...

Page 3: ...e Main menu Operation with TIMER The control unit can have a timer set up instead of an open close control button Example at 08 00 the timer closes the contact and the control unit opens the gate At 18 00 the timer opens the contact and the control unit closes the gate During the interval between 08 00 and 18 00 at the end of the opening phase the control unit disables the flashing beacon automati...

Page 4: ...le If you do not want the control unit to decelerate when the opening and closing phase is finished press the SET key twice during programming instead of just once During programming it is possible to use the radio control key located on the control unit instead of the SET key only if previously memorised 7 T MOT PED Programming a pedestrian operating time of 4 minutes max The control unit is fact...

Page 5: ... 5 sec after the photocell disengages i e the gate closes 5 seconds after the user has passed through If you wish to enable the function proceed as follows check that Extended Menu 1 is enabled T MOT PED and T PAUSA Leds flash simultaneously use the SEL button to move to the flashing PGM AUT LED and then press the SET key the PGM AUT LED will light up steady and programming is complete Repeat the ...

Page 6: ...Menu 2 is enabled T MOT PED and T PAUSA LEDs start flashing simultaneously use the SEL button to move to the flashing T MOT LED then press the SET key at that point the T MOT LED will light up steady and programming is complete Accordingly the PUL input makes it possible to connect a button NO for the Opening phase only and the BL input to connect a button NO for the Closing phase only Repeat the ...

Page 7: ...tion paragraph It is then advisable to make sure that the preselected band is free not already in use by another device To carry out this check do the following using the SET key move to the PROGRAMMING MENU the Base scans the preselected frequency and if it is already occupied by the Base the MONITOR LED and PROGR MENU LEDs will flash alternately In this case proceed to select a different frequen...

Page 8: ... is dismantled from an installation it is advisable to take the batteries out so that the Sensor no longer continues unnecessary transmission NC or 8K2 Operating Mode Selection The RTX 2252 Device allows NC normally closed contact standard type or 8K2 resistance type sensitive edges to be connected Use Dip Switch SW2 No 1 to make the selection DIP 1 OFF NC input operation default DIP 1 ON 8K2 inpu...

Reviews: