background image

                                                                                                 4                                                            rev. 3.0   13/06/2016 

 

programming LEDs will start to flash, indicating that it is not 
possible to memorise any more codes. 
Deletion. 
Memorised  codes  can  be  deleted  in  the  following  way:  press 
the  SEL  key,  the  CODE  LED  will  start flashing, then press the 
SET  key,  the  CODE  LED  will  switch  off  and  the  procedure  is 
finished. 
 
2) CODE PED:
(Code for the Ped./ S Door

 

 radio-control 

The  programming  and  deleting  procedure  is  the  same  as  the 
one  illustrated  above  except  that  the  selected  Led  should  be 
forPEDESTRIAN CODE. 
 
3)  INB.  CMD.  AP:  
(Command  inhibition  during  opening  and 
pause time, if entered) 
The  command  inhibition  function  during  opening  and  pause 
time,  if  entered,  is  used  when  automation  includes  a  loop 
detector.  During  the  opening  or  pause  phase  the  control  unit 
does not consider the commands sent by the loop detector with 
every passage. 
The factory settings of the control unit have disabled command 
inhibition  during  opening  and  pause  time.  If  it  is  necessary  to 
enable  it,  do  the  following:  use  the  SEL  key  to  move  to  the 
flashing  INB.CMD.AP  LED  then  press  the  SET  key.  The 
INB.CMD.AP  LED  will  light  up  steady. Repeat the procedure if 
you wish to restore the previous configuration. 
 
4)  LAMP/CORT.  :  
(Selection  of  the  flashing  light  or  the 
courtesy light) 
The  control  unit  has  a  230  Vac  output,  for  connection  to  a 
flashing light or a courtesy light. 
The  control  unit  is  supplied  by  the  manufacturer  with  the 
Flashing  function  enabled.  If  you  wish  to  enable  the  flashing 
beacon  function,  including  during  pauses,  proceed  as  follows: 
using  the  SEL  key  to  move  to  the  LAMP/CORT  flashing  LED 
then press the SET key, and the LAMP/CORT flashing LED will 
switch on steady.  
Repeat the operation if you wish to restore the factory setting. 
If  you  wish  to  enable  the  courtesy  light,  repeat  the  operation 
described  above,  pressing  the  SEL  button  twice  instead  of 
once  (making  the  LAMP/CORT  LED  flash  rapidly).

 

Repeat  the 

operation if you wish to restore the factory setting. 
 
5) PGM. AUT. : (Automatic Programming): 
With  this  control  unit  it  is  possible  to  carry  out  Automatic 
Programming ( SIMPLIFIED). 
First,  move  the  gates  to  their  half-way  position,  press  the  SEL 
button  until  the  PGM.  AUT.  LED  flashes  and  then  press  and 
hold the SET button down. The control unit completes the Auto 
programming  phase  by  executing  a  complete  opening  and 
closing phase (hold the SET key down until Auto Programming 
is  finished).  At  the  same  time,  the  Deceleration  cycle  is 
automatically configured at 15% of the complete cycle. 
During  Automatic  Programming,  you  can  use  the  radio-control 
key on the control unit instead of the SET key, only if previously 
memorised. 
 
6) T. MOT and DECELERATION:
 

(Programming a motor operation 

time of max 4 minutes) 

The  control  unit  is  factory  supplied  with  a  predefined  motor 
operating time of 30 sec. without deceleration. 
If  it  is  necessary  to  modify  the  motor  operating  time, 
programming  must  be  carried  out  when  the  gate  is  closed,  as 
follows:  use  the  SEL  key  to  move  to  the  flashing  T.MOT  LED,   
then press the SET key briefly. The Motor will begin its opening 
cycle.  When  it  starts  the  initial  point  of  deceleration,  press  the 
SET key again. At the same time, the motor will decelerate until 
it reaches the required position. Press the SET key to finish the 
opening cycle. The T. MOT LED  will then start flashing quickly. 
Now  repeat  motor  time  programming  and  the  deceleration 
operation  for  the  closing  cycle.  If  you  do  not  want  the  control 
unit  to  decelerate,  when  the  opening  and  closing  phase  is 
finished, press the SET key twice during programming, instead 
of just once.  

During  programming  it  is  possible  to  use  the  radio-control  key 
located  on  the  control  unit,  instead  of  the  SET  key,  only  if 
previously memorised. 
 
7)  T.  MOT.  PED:
 

(Programming  a  pedestrian  operating  time  of  4 

minutes max.) 

The control unit is factory supplied with a predefined Pedestrian 
Motor operating time of 10 sec. without deceleration. 
If  it  is  necessary  to  modify  the  pedestrian  operating  time, 
programming  must  be  carried  out  when  the  gate  is  closed,  as 
follows:  use  the  SEL  key  to  move  to  the  flashing  T.MOT  PED. 
LED,  then  press  the  SET  key  briefly.  The  Motor  will  start  the 
Opening cycle; press the SET key again at the point where you 
wish  to  start  deceleration:  the  T.  MOT.  PED.  LED    will  start 
flashing at a slower rate and the Motor will decelerate; when it 
reaches  the  required  point,  press  the  SET  key  to  finish  the 
Opening  cycle.  At  this  point  the  T.  MOT  PED.  LED  will  start 
flashing at its standard pace again and the Motor will begin the 
Closing  phase;  repeat  the  above  operations  for  the  Closing 
phase.  
If  you  do  not  want  the  control  unit  to  decelerate,  when  the 
opening and closing phase is finished, press the SET key twice 
during programming, instead of just once.  
During  programming  it  is  possible  to  use  the  radio-control  key 
located  on  the  control  unit,  instead  of  the  SET  key,  only  if 
previously memorised. 
 
8)  T.  PAUSA  (PAUSE  T.):
 

(Automatic  closing  time  programming 

max. 4 minutes) 

The control unit is factory supplied without automatic closing. 

If 

you wish to enable automatic closing, proceed as follows: 
using  the  SEL  key  to  move  to  the  flashing  T.  PAUSA 
LED, press the SET key briefly, then wait for the amount 
of time you wish to set for automatic closing; briefly press 
the  SET  key  again,  and  in  that  moment  the  automatic 
closing  time  will  be  memorised  and  the  T.  PAUSA  LED 
will stay on steady.

  If  you  wish  to  restore  the  initial  condition 

(without  automatic  closing),  move  to  the  flashing  T.  PAUSA 
LED, then press the SET key twice within 2 seconds. The Led 
will switch off and the operation will be finished. 
During  programming  it  is  possible  to  use  the  radio-control  key 
located  on  the  control  unit,  instead  of  the  SET  key,  only  if 
previously memorised. 
 

EXTENDED MENU 1 

     

The  control  unit  is  supplied  by  the  manufacturer  with  the 
possibility of directly selecting the main menu functions only. 
If you wish to enable the functions described in Extended Menu 
1,  proceed  as  follows:  press  and  hold  the  SET  button  for  5 
seconds,  after  which  amount  of  time  the  T.  MOT.  PED  and  T. 
PAUSA  LEDs  will  start  flashing  alternately.  The  user  then  has 
30  seconds  to  select  the  functions  for  Extended  Menu  1  from 
the SEL and SET buttons. After another 30 seconds the control 
unit will go back to the main menu. 
 

----------------------    EXTENDED MENU 1    ----------------- 

Led Reference Led Off Led On 

A) CODE                      Step-by-Step                       Inverting       
B) CODE PED     Electronic Brake = OFF      Electronic Brake= ON 
C) IN.CMD.AP.   Anti-collision=OFF Anti-collision APCH or CH=ON      
D) LAMP/CORT.  Deceleration = OFF       Deceleration = ON   
E) PGM. AUT.          Follow Me = OFF           Follow Me = ON     
F) T.MOT.                Encoder = OFF              Encoder = ON     
G) T. MOT.PED.                 Alternate ON/OFF flashing light                                      
H) T. PAUSA                       Alternate ON/OFF flashing light                   

 

A) CODE (

 Step-by-Step / Automatic Operation

 ) : 

The control unit is supplied by the manufacturer with Automatic 
mode  disabled.  If  you  wish  to  enable  the  function,  proceed  as 
follows:  make  sure  that  you  have  enabled  extended  menu  1 
(reported  by  alternately  flashing  T.  MOT  PED  Leds  and  T. 
PAUSA Led), by using the SEL key to select the flashing CODE 

Summary of Contents for LRX 2271

Page 1: ... up an isolating device inside the system It is necessary to install an omnipolar switch surge category III It must be positioned to provide protection from accidental closing pursuant to point 5 2 9 of EN 12453 6 For the power supply cables use flexible cables in an insulating sheath in harmonised polychloroprene H05RN F with a minimum conductor section of 1mm2 7 The various electrical components...

Page 2: ... Encoder Signal Input 3 GND Motor Encoder Power Supply OPERATING FEATURES Step by step operation By using either the radio control CODE led on or the low voltage buttons to activate the gate you obtain the following action the first impulse activates the opening mechanism until the motor time expires or the opening limit switch is reached the second impulse closes the gate If an impulse is sent be...

Page 3: ...e Main menu Operation with TIMER The control unit can have a timer set up instead of an open close control button Example at 08 00 the timer closes the contact and the control unit opens the gate At 18 00 the timer opens the contact and the control unit closes the gate During the interval between 08 00 and 18 00 at the end of the opening phase the control unit disables the flashing beacon automati...

Page 4: ...le If you do not want the control unit to decelerate when the opening and closing phase is finished press the SET key twice during programming instead of just once During programming it is possible to use the radio control key located on the control unit instead of the SET key only if previously memorised 7 T MOT PED Programming a pedestrian operating time of 4 minutes max The control unit is fact...

Page 5: ... 5 sec after the photocell disengages i e the gate closes 5 seconds after the user has passed through If you wish to enable the function proceed as follows check that Extended Menu 1 is enabled T MOT PED and T PAUSA Leds flash simultaneously use the SEL button to move to the flashing PGM AUT LED and then press the SET key the PGM AUT LED will light up steady and programming is complete Repeat the ...

Page 6: ...Menu 2 is enabled T MOT PED and T PAUSA LEDs start flashing simultaneously use the SEL button to move to the flashing T MOT LED then press the SET key at that point the T MOT LED will light up steady and programming is complete Accordingly the PUL input makes it possible to connect a button NO for the Opening phase only and the BL input to connect a button NO for the Closing phase only Repeat the ...

Page 7: ...tion paragraph It is then advisable to make sure that the preselected band is free not already in use by another device To carry out this check do the following using the SET key move to the PROGRAMMING MENU the Base scans the preselected frequency and if it is already occupied by the Base the MONITOR LED and PROGR MENU LEDs will flash alternately In this case proceed to select a different frequen...

Page 8: ... is dismantled from an installation it is advisable to take the batteries out so that the Sensor no longer continues unnecessary transmission NC or 8K2 Operating Mode Selection The RTX 2252 Device allows NC normally closed contact standard type or 8K2 resistance type sensitive edges to be connected Use Dip Switch SW2 No 1 to make the selection DIP 1 OFF NC input operation default DIP 1 ON 8K2 inpu...

Reviews: