4 rev. 3.0 13/06/2016
programming LEDs will start to flash, indicating that it is not
possible to memorise any more codes.
Deletion.
Memorised codes can be deleted in the following way: press
the SEL key, the CODE LED will start flashing, then press the
SET key, the CODE LED will switch off and the procedure is
finished.
2) CODE PED:(Code for the Ped./ S Door
radio-control
The programming and deleting procedure is the same as the
one illustrated above except that the selected Led should be
forPEDESTRIAN CODE.
3) INB. CMD. AP: (Command inhibition during opening and
pause time, if entered)
The command inhibition function during opening and pause
time, if entered, is used when automation includes a loop
detector. During the opening or pause phase the control unit
does not consider the commands sent by the loop detector with
every passage.
The factory settings of the control unit have disabled command
inhibition during opening and pause time. If it is necessary to
enable it, do the following: use the SEL key to move to the
flashing INB.CMD.AP LED then press the SET key. The
INB.CMD.AP LED will light up steady. Repeat the procedure if
you wish to restore the previous configuration.
4) LAMP/CORT. : (Selection of the flashing light or the
courtesy light)
The control unit has a 230 Vac output, for connection to a
flashing light or a courtesy light.
The control unit is supplied by the manufacturer with the
Flashing function enabled. If you wish to enable the flashing
beacon function, including during pauses, proceed as follows:
using the SEL key to move to the LAMP/CORT flashing LED
then press the SET key, and the LAMP/CORT flashing LED will
switch on steady.
Repeat the operation if you wish to restore the factory setting.
If you wish to enable the courtesy light, repeat the operation
described above, pressing the SEL button twice instead of
once (making the LAMP/CORT LED flash rapidly).
Repeat the
operation if you wish to restore the factory setting.
5) PGM. AUT. : (Automatic Programming):
With this control unit it is possible to carry out Automatic
Programming ( SIMPLIFIED).
First, move the gates to their half-way position, press the SEL
button until the PGM. AUT. LED flashes and then press and
hold the SET button down. The control unit completes the Auto
programming phase by executing a complete opening and
closing phase (hold the SET key down until Auto Programming
is finished). At the same time, the Deceleration cycle is
automatically configured at 15% of the complete cycle.
During Automatic Programming, you can use the radio-control
key on the control unit instead of the SET key, only if previously
memorised.
6) T. MOT and DECELERATION:
(Programming a motor operation
time of max 4 minutes)
The control unit is factory supplied with a predefined motor
operating time of 30 sec. without deceleration.
If it is necessary to modify the motor operating time,
programming must be carried out when the gate is closed, as
follows: use the SEL key to move to the flashing T.MOT LED,
then press the SET key briefly. The Motor will begin its opening
cycle. When it starts the initial point of deceleration, press the
SET key again. At the same time, the motor will decelerate until
it reaches the required position. Press the SET key to finish the
opening cycle. The T. MOT LED will then start flashing quickly.
Now repeat motor time programming and the deceleration
operation for the closing cycle. If you do not want the control
unit to decelerate, when the opening and closing phase is
finished, press the SET key twice during programming, instead
of just once.
During programming it is possible to use the radio-control key
located on the control unit, instead of the SET key, only if
previously memorised.
7) T. MOT. PED:
(Programming a pedestrian operating time of 4
minutes max.)
The control unit is factory supplied with a predefined Pedestrian
Motor operating time of 10 sec. without deceleration.
If it is necessary to modify the pedestrian operating time,
programming must be carried out when the gate is closed, as
follows: use the SEL key to move to the flashing T.MOT PED.
LED, then press the SET key briefly. The Motor will start the
Opening cycle; press the SET key again at the point where you
wish to start deceleration: the T. MOT. PED. LED will start
flashing at a slower rate and the Motor will decelerate; when it
reaches the required point, press the SET key to finish the
Opening cycle. At this point the T. MOT PED. LED will start
flashing at its standard pace again and the Motor will begin the
Closing phase; repeat the above operations for the Closing
phase.
If you do not want the control unit to decelerate, when the
opening and closing phase is finished, press the SET key twice
during programming, instead of just once.
During programming it is possible to use the radio-control key
located on the control unit, instead of the SET key, only if
previously memorised.
8) T. PAUSA (PAUSE T.):
(Automatic closing time programming
max. 4 minutes)
The control unit is factory supplied without automatic closing.
If
you wish to enable automatic closing, proceed as follows:
using the SEL key to move to the flashing T. PAUSA
LED, press the SET key briefly, then wait for the amount
of time you wish to set for automatic closing; briefly press
the SET key again, and in that moment the automatic
closing time will be memorised and the T. PAUSA LED
will stay on steady.
If you wish to restore the initial condition
(without automatic closing), move to the flashing T. PAUSA
LED, then press the SET key twice within 2 seconds. The Led
will switch off and the operation will be finished.
During programming it is possible to use the radio-control key
located on the control unit, instead of the SET key, only if
previously memorised.
EXTENDED MENU 1
The control unit is supplied by the manufacturer with the
possibility of directly selecting the main menu functions only.
If you wish to enable the functions described in Extended Menu
1, proceed as follows: press and hold the SET button for 5
seconds, after which amount of time the T. MOT. PED and T.
PAUSA LEDs will start flashing alternately. The user then has
30 seconds to select the functions for Extended Menu 1 from
the SEL and SET buttons. After another 30 seconds the control
unit will go back to the main menu.
---------------------- EXTENDED MENU 1 -----------------
Led Reference Led Off Led On
A) CODE Step-by-Step Inverting
B) CODE PED Electronic Brake = OFF Electronic Brake= ON
C) IN.CMD.AP. Anti-collision=OFF Anti-collision APCH or CH=ON
D) LAMP/CORT. Deceleration = OFF Deceleration = ON
E) PGM. AUT. Follow Me = OFF Follow Me = ON
F) T.MOT. Encoder = OFF Encoder = ON
G) T. MOT.PED. Alternate ON/OFF flashing light
H) T. PAUSA Alternate ON/OFF flashing light
A) CODE (
Step-by-Step / Automatic Operation
) :
The control unit is supplied by the manufacturer with Automatic
mode disabled. If you wish to enable the function, proceed as
follows: make sure that you have enabled extended menu 1
(reported by alternately flashing T. MOT PED Leds and T.
PAUSA Led), by using the SEL key to select the flashing CODE