26
12. If a “Leak Detected….> Internal pressure changed…” message appears during the leak analysis go back to
step 6. Inspect the O-rings for damage - replace O-rings if damaged. Clean the O-rings and repeat steps
6 through 11.
Note
•
You may disable the leak alarm in the app settings. Refer to page 37 for more details. Disabling the leak
alarm will stop the housing from alerting you if an air pressure or water leak is detected. If you disable the
leak alarm, it is still important to apply internal vacuum pressure, which helps the waterproof seal.