4.  SET up

4.1. 

  

Installing/Changing Battery (fig.1)

4.1.1.   

on either side of the trigger, where the handle moulding meets the main body there are two very  

 

 

 

 

 

shallow recesses. Place thumb and finger into these recesses and pull the front section of the handle   

 

 

 

 

forward and down to reveal the battery compartment.

4.1.2. 

  

Attach the battery connector to the battery terminals and place the battery into the battery compartment  

 

 

 

 

making sure that the connection leads will not foul the cover when it is closed.

4.1.3.   

When the ‘battery low’ indicator appears on the display replace the battery immediately,  

 

 

 

 

 

 

(See environmental Protection)

5.  OpERATION AND AppLIcATION

5.1. 

  

Depress the trigger (1) in fig 3 to switch on the unit, the ‘SCAN’ icon will illuminate.

5.2. 

  

Decide what units are required by pressing the ‘°C/°F’ button (3) in fig 3. The button will toggle  

 

 

between the specified units.

5.3.    

Pay attention to the distance from the thermometer to the target as the 

 

 

 

 

 

 

 

target surface size increases with distance. A ratio of 12:1 exists, see fig 2. 

 

 

 

 

 

 

 

make sure the target is larger than the unit’s spot size. The smaller the  

 

 

 

 

 

 

 

target, the closer the distance “d”. When accuracy is critical ensure the  

 

 

 

 

 

 

 

target is at least twice the spot size. 

5.4.    

The unit is equipped with a laser for the purpose of aiming only. With the 

 

 

 

 

 

 

 

laser button (2) in fig 3 in the ‘on’ or ‘off’ mode, aim at the target surface 

 

 

 

 

 

 

 

and depress the trigger. The temperature of the target surface will be   

 

 

 

 

 

 

 

displayed on the lCd display screen. When the trigger is released the  

 

 

 

 

 

 

 

reading will be held for 7 seconds approximately; the ‘Hold’ icon will  

 

 

 

 

 

 

 

be illuminated in this period; and then the thermometer will automatically  

 

 

 

 

 

 

 

shut down unless the trigger is depressed again.

5.5.    

To locate a hot spot on a large surface, aim the thermometer as in 4.4, then scan across the area with a controlled uniform “zig-zag”  

 

sweep until 

you locate the spot, as illustrated in fig 4. 

6.  NOTES ON EMISSIVITy

6.1.    

emissivity is a term used for the ability of a surface to radiate energy. This unit has been pre-set with an emissivity of 0.95, which  

 

makes it suitable for 90% of typical applications.

6.2.    

Inaccurate results will occur when targeting shiny or polished surfaces. As a tip, apply a non reflective tape to the area to be  

 

 

tested allowing time for the surface temperature of the tape to reach that of the substrate.

7.  cLEANING

7.1.    

The sensor lens is delicate and should be kept clean at all times. Use a cotton bud and medical alcohol, allowing lens to dry. The   

 

casing can be cleaned with a moist cloth and mild soap but never submerged.

2) laser

  on/off

3) Units 

°C/°F

4) Back light 

on/off

1)Trigger

fig.3

Trigger

depressed

fig.4

fig.1

fig.2

VS900.V3 Issue 3 (HF) 11/04/18

Original Language Version

© Jack Sealey limited

A

B

C

d

e

G

F

lCd display-:

A: Data hold icon

B: Scanning icon

C: laser "on" icon

d: Backlight "on" icon

e: Battery status icon

F: Temperature units (°C or °F)

G: Temperature reading 