background image

 
 
 
 
 
 
 

Instruction Manual 

 

Wall-Mount Type Waterproof Digital Thermometer   

Model SK-100WP 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SK-100WP

Page 1: ...Instruction Manual Wall Mount Type Waterproof Digital Thermometer Model SK 100WP ...

Page 2: ... use this unit in a place exposed to direct sunlight or near heating equipment Doing so may result in deformation of the casing or failure Do not use this unit in an environment where electrical noise is generated Doing so may result in unstable display or larger errors If this unit is not to be used for a long time always remove the batteries from the unit Otherwise the batteries may leak fluid r...

Page 3: ...tion even if the unit is immerged in water depth 1m for 30 minutes under normal temperature However this instrument cannot be used in water A large LCD display for easy reading Simple operation function is Power ON OFF only 4 Names of Section 4 1 Main housing Front view Rear view POWER ON OFF key Press this key to turn the main unit on Press the key again to turn it off Display section displays me...

Page 4: ...ery lid 2 Load four AAA batteries so that each positive or negative terminal faces the correct direction 3 Reinstall the battery lid and secure with the screw in the reverse order of the removal procedure If you have a torque driver firmly secure with about 0 40 N m Otherwise Waterproofness will not be guaranteed Warning When the low battery mark blinks replace the batteries with new ones Otherwis...

Page 5: ...aracters are displayed for 3 sec Then the current temperature will be displayed and it enters the measurement mode 2 Insert the sensor stem into the object to be measured and read the temperature value after the indication becomes stable 3 Press the ON OFF key again and the display will disappear and power will be off 7 Error Message Display Causes Remedy E02 Probe is not connected Measured value ...

Page 6: ... 1 Sampling time approx 10 sec Waterproof Proper Conforming to JIS C0920 Protection Class 7 Equivalent to IP X7 rated Operation ambient 0 to 50 Storage ambient 10 to 50 Power requirements AAA size battery x 4 pcs Battery life About 1 year continuous with alkali batteries in normal temperature Materials ABS resin Dimensions 122 W 85 H 30 D mm Weight Approx 205g including batteries Standard accessor...

Page 7: ...No 3 Nishi Fukudacho Kanda Chiyodaku Tokyo 101 0037 Japan URL http www sksato co jp english ...