background image

           
 

 

    OPERATING INSTRUCTIONS 

 

Digital Thermometer 

 
                   

ZI-9613 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

www.zicotech.com 

 
 

INTRODUCTION 

This  instrument  is  a  portable  3

1

/

2

  digit., 

compact-sized  digital  thermometer  designed  to 
use  external  K-type  thermocouple  as  temperature 
sensor.  Temperature  indication  follows  National 
Bureau 

of 

Standards 

and 

IEC584 

temperature/voltage 

tables 

for 

K-type 

thermocouples.  two  K-type  thermocouples  is 
supplied with the thermometer. 
 

SAFETY INFORMATION 

It  is  recommended  that  you  read  the  safety  and 
operation instructions before using the thermometer. 

WARNING 

TO  AVOID  ELECTRICAL  SHOCK.  DO  NTO 
USE  THIS  INSTRUMENT  WHEN  VOLTAGES 
AT  THE  MEASUREMENT  SURFACE  EXCEED 
24V AC OR 60V DC. 

WARNING 

TO  AVOID  DAMAGE  OR  BURNS.  DO  NOT 
MAKE TEMPERATURE MEASUREMENTS IN 
MICROWAVE OVENS. 

CAUTION 

Repeated 

sharp 

flexing 

can 

break 

the 

thermocouple  leads.  To  prolong  lead  life,  avoid 
sharp  bends  in  the  leads,  especially  near  the 
connector. 
The      symbol  on  the  instrument  indicates  that 
the  operator  must  refer  to  an  explanation  in  this 
manual. 

 

SPECIFICATIONS ELECTRICAL 
Temperature Scale: 

Celsius (

), Fahrenheit (

) user-selectble 

Measurement Range: 

-50

  to 1300

, -58

  to 2000

 

Resolution: 

1

  or 1

, 0.1

  or 0.1

 

Accuracy: 

Accuracy  is  specified  for  operating  temperatures 
over the range of 18

to 28

(64

  to 82

), for l 

year, not including thermocouple error. 

±

2

----------------------    -50

  to 0

 

±

4

----------------------    -58

  to 32

 

±

(0.5% rdg+1

)--------    0

  to 1000

 

±

(0.8% rdg+1

)--------    1000

  to 1300

 

±

(0.5% rdg+2

)--------    32

to 2000

 

 

Temperature Coefficient: 

0.1  times  the  applicable  accuracy  specification 
per 

  from 0

  to 18

  and 28

  to 50

  (32

  to 64

  and 82

  to 122

). 

Input protection: 

60V de or 24V rms ac maximum input voltage on 
any combination of input pins. 

Reading Rate: 

2.5 times per second. 

Input Connector: 

Accepts  standard  miniature  thermocouple  connectors 
(flat blades spaced 7.9mm, center to center). 
 

ENVIRONMENTAL 
Ambient Operating Range: 

0

  to 50

  (32

  to 122

Storage Temperature: 
-20

  to 60

  (-4

  to 140

Relative Humidity: 

0% to 80% (0

  to 35

) (32

  to 95

0% to 70% (35

  to 50

) (95

  to 122

 

GENERAL 
Display: 

3

1

/

2

  digit  liquid  crystal  display  (LCD)  with 

maximum reading of 1999 

Battery: 

Standard 9V battery (NEDA 1604, IEC 6F22) 

Dimensions: 

162mm (H)

×

76mm(W)

×

38.5mm(D) 

Weight: 

210g 

Supplied Probe:   

4  foot  type"K"thermocouple  bead  probe  (Teflon 
tape insulated). 
Maximum insulation temperature 260

(500

)   

Probe  accuracy

±

2.2

  or 

±

0.75%  of  reading 

(Whichever is greater) from 0

°

to 800

 

 

OPERATING INSTRUCTIONS 

 

Selecting the Temperature Scale 

Readings  are  displayed  in  either  degrees  Celsius 
(

),  degrees  Fahrenheit  (

).When  the 

thermometer  is  turned  on,  it  is  set  to  the 
temperature  scale  that  was  in  use  when  the 
thermometer  was  last  turned  off.  To  change  the 
temperature scale, press the For

  or 

key. 

 

Single-Thermocouple Temperature Measurement 

The  thermometer  displays  the  temperature  of  the 

Reviews: