Range

Range Resolution Accuracy Overload protection

200mA

0.1mA

±(0.8%+5)

Ce: Fuse 315mA, 

250V, fast type, 

5x20mm

10A

10mA

±(1.2%+5) Ce: Fuse 10A, 250V, 

fast type, 5x20mm

dC Current

Resolution Overload protection

1mV

600Vp

diode

Range Resolution Accuracy Overload protection

4CYl

0.1º

6CYl
8CYl

600Vp

±(3%+5)

dwell testing

Range Resolution Accuracy Overload protection

4CYl

10RPM

6CYl
8CYl

600Vp

±(3%+5)

Tach (rotation speed) testing

Input amplitude: 

≥ 

10V in direct impulse; 

 0.5mS in width.

Input amplitude: 

≥ 

10V in direct impulse; 

 0.5mS in width.

Maximum tach: 10000 RPM, displayed as RPM x10. 

Environmental Protection.

 

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging  

 

 

should be sorted, taken to a recycle centre and disposed of in a manner which is compatible with the

 

environment.

 

When the product is no longer required, it must be disposed of in an environmentally protective way. Contact    

 

your local solid waste authority for recycling information.

 

WARNING:

 do not dispose of by fire.This could result in an explosion. 

 

Before disposing of battery, cover exposed terminals with heavy duty electrical tape to prevent shorting. 

 

DO NOT

 expose battery to intense heat or fire as this could cause an explosion.

 

 

Battery Removal: See Section 5.3.     

 

ONlY dispose of or recycle according to local authority regulations. Under the Waste Batteries and    

 

 

Accumulators Regulations 2009, Jack Sealey ltd are required to inform potential purchasers of products 

 

containing batteries (as defined within these regulations), that they are registered with Valpak’s registered 

 

compliance scheme. Jack Sealey ltd’s Batteries Producer Registration Number (BPRN) is BPRN00705.

Summary of Contents for TA200

Page 1: ... meter terminals When the scale of the value to be measured is unknown set the selector to the highest range available Before rotating the rotary switch to change functions disconnect test leads from the circuit under test WARNING Never perform resistance measurements on live circuits Always be careful when working with voltages above 60Vdc or 30Vac rms Keep your fingers behind the probe guards wh...

Page 2: ...ates an AC voltage or current The displayed value is the mean value Indicates a negative reading Diode test Continuity buzzer is on Data hold function is active Indicates the requirement for test leads to be connected Ω Ohm The unit of resistance kΩ kilohm 1x103 or 1000 ohms MΩ Megaohm 1x106 or 1 000 000 ohms V Volts The unit of voltage mV Millivolt 1x10 3 or 0 001 volts A Amperes amps The unit of...

Page 3: ...nt path to be tested connect the red test lead to the positive side of the break and the black test lead to the negative side of the break i e connect the meter in series 4 2 6 Turn on reconnect power to the circuit The measured value is shown on the display When the measurement has been completed disconnect the test leads from the circuit being tested Note Within the 10A range the meter must not ...

Page 4: ... tested is open Open circuit voltage is approx 2 7V When continuity testing has been completed disconnect the connection between the testing leads and the circuit under test 4 6 Dwell testing fig 7 4 6 1 This function can be used to test the dwell of the cut off switch points or electronic of an ignition system 4 6 1 1 Turn the rotary switch to the appropriate setting within the DWELL function are...

Page 5: ...cloth and mild detergent DO NOT use abrasives or solvents 5 1 2 Clean the terminals with a cotton bud and mild detergent to prevent the build up of dirt moisture in the terminals which may affect readings 5 1 3 Turn the meter off when not in use and remove the battery if the meter is not to be used for some time 5 2 To replace the fuses 5 2 1 Turn the meter off and disconnect any leads equipment f...

Page 6: ... 5 Tach rotation speed testing Input amplitude 10V in direct impulse 0 5mS in width Input amplitude 10V in direct impulse 0 5mS in width Maximum tach 10000 RPM displayed as RPM x10 Environmental Protection Recycle unwanted materials instead of disposing of them as waste All tools accessories and packaging should be sorted taken to a recycle centre and disposed of in a manner which is compatible wi...

Reviews: