background image

4.4.  Diode testing (fig 6)

  

WARNING! To avoid damage to the meter and/or devices being tested, disconnect  

 

circuit power and discharge all high-voltage capacitors before testing diodes.

 

Never attempt an in-circuit current measurement where the open circuit voltage  

 

between terminals and ground is greater than 60V DC or 30V AC rms. 

 

Use the diode test to check diodes, transistors, and other semiconductor devices. The diode  

 

test sends current through the semiconductor junction, then measures the voltage drop  

 

across the junction. A good silicon junction drops between 0.5V and 0.8V 

4.4.1. To test a diode out of circuit, connect the meter as follows:

4.4.2. Insert the red test lead into the    terminal and the black test lead into the COM terminal.

4.4.3. Set the rotary switch to           . 

4.4.4. For forward voltage drop readings on any semiconductor component, place the red test lead  

 

on the components anode (+) and place the black test lead on the components cathode (-).  

 

The measured value will be displayed. 

 

Note: In a circuit, a good diode should still produce a forward voltage drop reading of 0.5- 

 

0.8V but the reverse voltage drop reading can vary depending on the resistance of other  

 

pathways between the probe tips. 

 

Connect the test leads to the appropriate terminals as described in section 4.4.2 to avoid  

 

error display. 

 

The open circuit voltage is around 2.7V when testing a diode. 

 

The LCD will display “1” indicating open-circuit if the meter test leads are incorrectly   

 

connected. 

 

When diode test has been completed, disconnect the test leads from the circuit being tested. 

4.5.  Continuity testing  

  

WARNING! To avoid damage to the meter and to the device being tested, disconnect  

 

circuit power and discharge all high-voltage capacitors before testing continuity.  

 

Never attempt an in-circuit current measurement where the open circuit voltage  

 

between terminals and ground is greater than 60V DC or 30V AC rms. 

4.5.1. To test for continuity, connect the meter as you would for diode testing (see section 4.4).

4.5.2. Connect the test leads across the object/circuit being tested.
4.5.3. If the resistance value is >50

Ω 

(i.e. the circuit is damaged/disconnected) the buzzer will not  

 

sound.

4.5.4. The buzzer sounds continuously when the resistance is 

30

Ω. 

The circuit is operational.

 

Note: The LCD displays “1” indicating the circuit being tested is open. 

 

Open circuit voltage is approx 2.7V.

 

When continuity testing has been completed, disconnect the connection between the testing  

 

leads and the circuit under test.  

4.6.  Dwell testing (fig 7) 

4.6.1. This function can be used to test the dwell of the cut-off switch (points or electronic) of an  

 

ignition system. 

 

4.6.1.1.  Turn the rotary switch to the appropriate setting within the “dWell” function area. There  

 

 

is a choice between 4, 6 & 8 cylinders. Choose the setting appropriate to the engine in  

 

 

question. 

4.6.1.2.  Insert the red test lead into the      terminal and the black test lead into the COM 

 

 

terminal. Connect the ends to be tested as shown in fig 7. 

4.6.1.3.  When testing the cut-off switch of an ignition system, connect the red test lead probe to  

 

 

the primary negative end of the ignition coil (refer to the vehicle service manual for the  

 

 

specific position).  

4.6.2. If the dwell of arbitrary ON/OFF equipment is to be tested, connect the red probe to the  

 

end of the equipment in question fitted with an ON/OFF switch. 

4.6.3. Connect the black test lead probe to the good ground terminal of the automobile.

4.6.4. The measured dwell will be displayed on the lCd. 

4.7.  Engine tach (rotation speed) RPM x 10 (fig 8)

 

 

engine tach RPM is the number of rotations completed by the main shaft of the engine per  

 

minute. 

4.7.1. Turn the rotary switch to the appropriate setting within the “RPM x 10” function area. There is  

 

a choice between 4, 6 & 8 cylinders. Choose the setting appropriate to the engine in  

 

question.

4.7.2. Insert the red test lead into the   terminal and the black lead into the COM terminal.  

 

Connect the ends to be tested as shown in fig 8. 

4.7.2.1.  If the vehicle uses a dIS ignition system with no distributor board, connect the red test  

 

 

lead probe to the TACH (tachometer) signal line (which is connected to the computer dIS  

 

 

module of the engine). Refer to the vehicle service manual for the specific location. 

4.7.2.2.  If the vehicle uses an ignition system with a distributor board, connect the red test lead  

 

 

probe to the primary negative end of the ignition coil. Refer to the vehicle service manual  

 

 

for the specific location. 

4.7.3. Connect the black test lead probe to the good ground terminal of the automobile. 

4.7.4. On starting the engine or whilst it is running, test the rotation speed of the engine and read  

 

the value displayed. The display is RPM ÷ 10 i.e. the actual rotation speed is obtained by 

 

multiplying the displayed value by 10. 

 

Fig 6

Fig 7

Fig 8

 TA200      Issue No: 3 - 19/12/11

Original Language Version

Summary of Contents for TA200

Page 1: ... meter terminals When the scale of the value to be measured is unknown set the selector to the highest range available Before rotating the rotary switch to change functions disconnect test leads from the circuit under test WARNING Never perform resistance measurements on live circuits Always be careful when working with voltages above 60Vdc or 30Vac rms Keep your fingers behind the probe guards wh...

Page 2: ...ates an AC voltage or current The displayed value is the mean value Indicates a negative reading Diode test Continuity buzzer is on Data hold function is active Indicates the requirement for test leads to be connected Ω Ohm The unit of resistance kΩ kilohm 1x103 or 1000 ohms MΩ Megaohm 1x106 or 1 000 000 ohms V Volts The unit of voltage mV Millivolt 1x10 3 or 0 001 volts A Amperes amps The unit of...

Page 3: ...nt path to be tested connect the red test lead to the positive side of the break and the black test lead to the negative side of the break i e connect the meter in series 4 2 6 Turn on reconnect power to the circuit The measured value is shown on the display When the measurement has been completed disconnect the test leads from the circuit being tested Note Within the 10A range the meter must not ...

Page 4: ... tested is open Open circuit voltage is approx 2 7V When continuity testing has been completed disconnect the connection between the testing leads and the circuit under test 4 6 Dwell testing fig 7 4 6 1 This function can be used to test the dwell of the cut off switch points or electronic of an ignition system 4 6 1 1 Turn the rotary switch to the appropriate setting within the DWELL function are...

Page 5: ...cloth and mild detergent DO NOT use abrasives or solvents 5 1 2 Clean the terminals with a cotton bud and mild detergent to prevent the build up of dirt moisture in the terminals which may affect readings 5 1 3 Turn the meter off when not in use and remove the battery if the meter is not to be used for some time 5 2 To replace the fuses 5 2 1 Turn the meter off and disconnect any leads equipment f...

Page 6: ... 5 Tach rotation speed testing Input amplitude 10V in direct impulse 0 5mS in width Input amplitude 10V in direct impulse 0 5mS in width Maximum tach 10000 RPM displayed as RPM x10 Environmental Protection Recycle unwanted materials instead of disposing of them as waste All tools accessories and packaging should be sorted taken to a recycle centre and disposed of in a manner which is compatible wi...

Reviews: