3.2.

 

Display (Fig 2)

 

 

The lCd displays the 

 

measured values obtained in  

 

tests and various other 

 

information regarding the  

 

state/operation of the meter.  

 

The following is an illustration  

 

and descriptive list to enable  

 

the user to understand the  

 

information presented. 

Battery is low. 

Replace immediately using a PP3 9V 

battery. Failure to do so could lead to 

inaccurate readings. 

Indicates an AC voltage or current.

The displayed value is the mean value

Indicates a negative reading
diode test

Continuity buzzer is on
data hold function is active

Indicates the requirement for test leads 

to be connected. 

:   Ohm. The unit of resistance.

k

Ω: 

kilohm. 1x103 or 1000 ohms.

M

Ω: 

Megaohm. 1x106 or 

 

1,000,000 ohms. 

V:  Volts. The unit of voltage.

mV: Millivolt. 1x10-3 or 0.001 volts

A:  Amperes (amps). The unit of 

 

current. 

mA: Milliamp. 1x10-3 or 0.001 amperes

Test of dwell. 
Tach x 10

Number of cylinders

Fig 2

Caution - high voltage testing 

 TA200      Issue No: 3 - 19/12/11

Original Language Version

Summary of Contents for TA200

Page 1: ... meter terminals When the scale of the value to be measured is unknown set the selector to the highest range available Before rotating the rotary switch to change functions disconnect test leads from the circuit under test WARNING Never perform resistance measurements on live circuits Always be careful when working with voltages above 60Vdc or 30Vac rms Keep your fingers behind the probe guards wh...

Page 2: ...ates an AC voltage or current The displayed value is the mean value Indicates a negative reading Diode test Continuity buzzer is on Data hold function is active Indicates the requirement for test leads to be connected Ω Ohm The unit of resistance kΩ kilohm 1x103 or 1000 ohms MΩ Megaohm 1x106 or 1 000 000 ohms V Volts The unit of voltage mV Millivolt 1x10 3 or 0 001 volts A Amperes amps The unit of...

Page 3: ...nt path to be tested connect the red test lead to the positive side of the break and the black test lead to the negative side of the break i e connect the meter in series 4 2 6 Turn on reconnect power to the circuit The measured value is shown on the display When the measurement has been completed disconnect the test leads from the circuit being tested Note Within the 10A range the meter must not ...

Page 4: ... tested is open Open circuit voltage is approx 2 7V When continuity testing has been completed disconnect the connection between the testing leads and the circuit under test 4 6 Dwell testing fig 7 4 6 1 This function can be used to test the dwell of the cut off switch points or electronic of an ignition system 4 6 1 1 Turn the rotary switch to the appropriate setting within the DWELL function are...

Page 5: ...cloth and mild detergent DO NOT use abrasives or solvents 5 1 2 Clean the terminals with a cotton bud and mild detergent to prevent the build up of dirt moisture in the terminals which may affect readings 5 1 3 Turn the meter off when not in use and remove the battery if the meter is not to be used for some time 5 2 To replace the fuses 5 2 1 Turn the meter off and disconnect any leads equipment f...

Page 6: ... 5 Tach rotation speed testing Input amplitude 10V in direct impulse 0 5mS in width Input amplitude 10V in direct impulse 0 5mS in width Maximum tach 10000 RPM displayed as RPM x10 Environmental Protection Recycle unwanted materials instead of disposing of them as waste All tools accessories and packaging should be sorted taken to a recycle centre and disposed of in a manner which is compatible wi...

Reviews: