background image

SA951015, SA952515 & SA955015 - 1 - 310105

1. SAFETY INSTRUCTIONS

1.1

ELECTRICAL SAFETY

WARNING!

It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any 

other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety 

devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a 

Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply 

which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting

your Sealey dealer. 

You must

also read and understand the following instructions concerning electrical safety.

1.1.1 The 

Electricity at Work Act 1989 

requires all portable electrical appliances, if used on business premises, to be tested by a qualified 

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2 The 

Health & Safety at Work Act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances 

and the safety of the appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3 Ensure that the insulation on all cables and on the appliance is safe before connecting it to 

the power supply. See 1.1.1 and 1.1.2 and use a Portable Appliance Tester.

1.1.4 Ensure that cables are always protected against short circuit and overload.

1.1.5 Regularly inspect power supply cables and plugs for wear or damage and check all

connections to ensure that none is loose.

1.1.6

Important:

Ensure that the voltage marked on the appliance matches the power supply 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7

DO NOT

pull or carry the appliance by the power cable.

1.1.8

DO NOT 

pull the plug from the socket by the cable.

1.1.9

DO NOT

use worn or damaged cables, plugs or connectors. Immediately have any faulty 

item repaired or replaced by a qualified electrician. When an ASTA/BS approved UK 

3 pin plug is damaged, cut the cable just above the plug and 

dispose of the plug safely. 

Fit a new plug according to the following instructions (UK only).

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

b)Connect the BROWN live wire to the live terminal ‘L’.

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

d)After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer 

insulation extends beyond the cable restraint and that the restraint is tight.

Double insulated products, which are always marked with this symbol      , are fitted with live (brown) and neutral (blue) wires only. 

To rewire, connect the wires as indicated above - 

DO NOT

connect either wire to the earth terminal.

1.1.10 Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure 

that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket 

with your electrician.

1.1.11 If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance 

plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that 

the capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the 

use of 2.5mm² section cable. If extension reel is to be used outdoors, ensure it is marked for outdoor use.

1.2

GENERAL SAFETY INSTRUCTIONS

1.2.1 Familiarise yourself with the application and limitations of the compressor. 

1.2.2 Ensure the compressor is in good order and condition before use. If in any doubt do not use the unit and contact an electrician/service

agent.

p

p

WARNING! Compressor must only be serviced by an authorised agent. DO NOT tamper with, or attempt to adjust pressure 

switch or safety valve.

1.2.3 Before moving, or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has been 

vented. 

1.2.4 Only use recommended attachments and parts. To use non-recommended items may be dangerous and will invalidate your warranty.

1.2.5 Read the instructions regarding any accessory used with the compressor. Ensure the safe working pressure of any air appliance used,

exceeds units output pressure. If using spray gun, check the area selected for spraying is provided with air change system/ventilation.

1.2.6 Ensure the air supply valve is turned off before disconnecting the air supply hose.

1.2.7 To move the compressor use the handle only. Lift the compressor so that the front leg gives enough clearance for manoeuvring but 

maintain units centre of gravity in front of the wheels. DO NOT attempt to lift or move the compressor by any means other than by 

handle. 

1.2.8 Use the compressor in a well ventilated area and ensure it is placed on a firm surface.

1.2.9 Keep tools and other items away from the compressor when it is in use, and keep area clean and clear of unnecessary items.

1.2.10 Ensure the air hose is not tangled or twisted, or pinched.

1.2.11 Keep children and unauthorised persons away from the working area.

7

7

DO NOT

dis-assemble compressor for any reason. This unit must be checked and serviced by an approved service agent.

7

7

DO NOT

use the compressor outdoors, or in damp, or wet locations, and DO NOT operate within the vicinity of flammable liquids, 

gases or solids.

FUSE RATING 13 AMP

Blue

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

Brown

Live 

Wire

INSTRUCTIONS FOR:

DIRECT DRIVE OIL FREE 

COMPRESSORS

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and

properly maintained, give you years of trouble free performance.

IMPORTANT

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND

CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO

MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.

MODELS:

SA951015

SA952515

SA955015

Summary of Contents for SA951015

Page 1: ...ase you must contact a qualified electrician to ensure that a suitably rated supply is available We recommend that you discuss the installation of an industrial round pin plug and socket with your electrician 1 1 11 If an extension reel is used it should be fully unwound before connection A reel with an RCD fitted is preferred since any appliance plugged into it will be protected The cable core se...

Page 2: ...ct to perform a task for which it has not been designed 7 7 DO NOT deface the certification plate attached to the tank 7 7 DO NOT cover the compressor or restrict air flow around the machine whilst operating s s DANGER DO NOT direct the output jet of air towards people or animals 7 7 DO NOT allow anyone to operate the compressor unless they have received full instructions p WARNING The air tank is...

Page 3: ...sure The pressure applied to the tool is shown on the output pressure gauge fig 1 7 4 3 3 Turn on tap fig 1 3 NOTE To determine the correct working pressure and air flow requirements for any piece of equipment check the corresponding manual Be aware that the air flow figure stated on tools and accessories refers to Free Air Delivery and not the piston displacement of the compressor 4 3 4 To discon...

Page 4: ...ose leaking The head screws are too tight item 15 Bearing fault Back off 1 4 turn Check seals or renew hose Loosen the screws and then tighten them equally do not overtighten Return to dealer for checking Safety valve operates below max pressure Faulty valve www sealey co uk 01284 757500 01284 703534 sales sealey co uk Web email Sole UK Distributor Sealey Group Bury St Edmunds Suffolk NOTE It is o...

Reviews: