background image

4.   MOUNTING THE HOSE REEL

 

ˆ

   WARNING! Ensure that the hose is disconnected from the air supply. DO NOT position the reel in direct sunlight, in areas of    

  extreme heat or cold or where it will be a hazard.

4.1. 

  

MOUNTING

4.1.1. 

  

Ensure that the wall, floor, ceiling or other structure to which the air hose reel is to be fixed is of sound construction and will hold the   

 

working strain of the hose when in use.

4.1.2.    Screw or bolt the reel to the mounting surface (see fig.1 for mounting hole dimensions). Adjust the guide arm (7) to suit the  

 

      installation. Remove the four clamping nuts (42), washers (41) and bolts (40), reposition the arm and then replace t

he bolts,  

 

 washe

rs and screws. Typical examples are shown in fig.2.

4.1.3. 

  

Fit the inlet hose (provided) to the inlet fitting (24) using thread 

s

ealer or PTF

E tape

The free end of the inlet hose should be    

 

connected to the air supply.

4.1.4. 

  

Before use, check that all fixings are safe and secure, and that the h

ose extends and

 retracts with ease.

5.  OPERATION

5.1. 

  

Pull the hose outward. An intermittent clicking noise will be noticed as the hose extends. 

5.2. 

  

If you stop pulling the hose whilst the clicking noise can be heard it will remain locked at that length. 

5.3. 

  

To extend the hose further, pull and again stop whilst the clicking noise can be heard to lock the hose.

5.4. 

  

To unlock the hose and allow it to automatically rewind, extend the hose a little further and release during a quiet stage between    

 

the periods of clicking. 

DO NOT

 allow the reel to rewind in an uncontrolled manner, always feed the hose to the reel.

5.5. 

  

Re-tensioning the hose reel

 

ˆ

  

WARNING!

 Ensure that the air supply is disconnected. 

5.5.1.   

Pull approximately 2mtr of hose from the drum and allow the drum to lock.

5.5.2.   

Remove the hose bumper blocks (55) and draw the 2mtr of hose back through the hose guide.

5.5.3.   

Wrap the hose one turn around the drum to increase the tension or unwrap one turn to decrease the tension.

5.5.4.   

Feed the end of the hose back through the hose guide and refit the bumper blocks.

5.5.5.   

Check the tension and adjust further, as above, if necessary.

6.  MAINTENANCE

 

ˆ

   WARNING!

 Before attempting maintenance or inspection, vent any pressure remaining in the hose.

 

6.1. 

  

To ensure reliable operation, clean the hose and casing regularly.  

DO NOT

 spray or wet the product, but clean with a damp cloth.    

 

DO NOT

 use solvents or detergents, as these may cause permanent damage. 

6.2. 

  

The hose reel does not require special maintenance as it is lubricated for life. If the product needs attention, consult your  

 

nearest authorised service agent. 

 

ˆ

   WARNING: DO NOT attempt to loosen, or remove, any casing nuts or bolts yourself, other than to reposition the hose    

  guide (see 4.1.2.).

 

6.3. 

 

 

Replacement of the supply hose should be carried out by skilled personnel only,

 consult your nearest authorised service    

 

agent.

6.4. 

  

Should you wish to store the air hose reel, ensure that it is clean and dry. Place in a dark, safe, dry, childproof location, where the  

 

temperature will remain reasonably stable. 

DO NOT

 store in a nylon, or plastic, bag as this will encourage condensation.

fig.2

fig.1

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without 

prior notice.

Important

: No Liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 

unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 

according to local regulations.

 SA84.V2  SA841.V2/HV.V2  SA85.V3  Issue:1 - 07/11/17

 © Jack Sealey Limited

Original Language Version