80
Product Manual - Disc Drive SCSI-2/SCSI-3 Interface (Vol. 2; Ver. 2), Rev. E
_____________________________________________________________________________________
continued from previous page
Byte
Byte
12
13
Description
20
00
Invalid Command Operation Code
21
00
Logical Block Address Out Of Range
24
00
Invalid Field In CDB
25
00
Logical Unit Not Supported
26
00
Invalid Field In Parameter List
26
01
Parameter Not Supported
26
02
Parameter Value Invalid
26
03
Invalid Field Parameter - Threshold Parameter
26
98
Invalid Field Parameter - Check Sum
26
99
Invalid Field Parameter - Firmware Tag
27
00
Write Protected
28
00
Not-Ready to Ready Transition; medium may have changed
29
00
Power On, Reset, Or Bus Device Reset Occurred
29
01
Power-On Reset occurred
2A
00
Parameters Changed
2A
01
Mode Parameters Changed
2A
02
Log Parameters Changed
2F
00
Tagged Commands Cleared By Another Initiator
31
00
Medium Format corrupted
31
01
Format Failed
32
00
No Defect Spare Location Available
37
00
Parameter Rounded
3D
00
Invalid Bits in Identify Message
3E
00
Logical Unit has Not Self Configured yet
3F
00
Target Operating Conditions have changed
3F
01
Microcode Changed
3F
02
Changed Operating Definition
40
01
DRAM Parity Error
42
00
Power-On or Self-Test Failure
43
00
Message Error
44
00
Internal Target Failure
45
00
Select/Reselection Failure
47
00
SCSI Parity Error
48
00
Initiator Detected Error Message Received
49
00
Invalid Message Error
4C
00
Logical Unit Failed Self-Configuration
4E
00
Overlapped Commands Attempted
5B*
00
Log Exception
5B*
01
Threshold Condition Met
5B*
02
Log Counter At Maximum
5B*
03
Log List Codes EXHAUSTED
5C
00
RPL Status Change
5C
01
Spindles Synchronized
5C
02
Spindles Not Synchronized
65
00
Voltage Fault
80
00
General Firmware Error Qualifier
*Note.