Troubleshooting
39
5.3.6 SBB I/O Module LEDs
The LEDs on the SBB I/O module will depend on the type of module in use. LEDs for a common I/O
module (the 12Gb/s SAS EBOD) are shown in
and described below.
Figure 5–6
12Gb/s SAS EBOD I/O Module LEDs
Table 5–5
12Gb/s SAS EBOD I/O Module LED Descriptions
LED
Description
I/O Module Status
Constant green if the I/O module is operating correctly.
I/O Module Fault
Constant amber if the I/O module is faulty. For replacement procedure see
section
6.6, “Replacing an SBB I/O Module”, on page 53
I/O Module Identity
(ID)
Blinking blue if host has set identify for canister via SES.
External Host Port Fault Constant amber indicates that there is a critical fault, a fault causing
operation of the cable to cease, or fail to start (for example, over current
trip).
Flashing amber indicates that there is a non-critical fault - a fault which does
not cause the connection to cease operation (for example, not all links
established).
External Host Port
Activity
Constant green indicates that there is a host port connection but no activity.
Flashing green indicates that there is a host port connection, and data is
being transferred.
Summary of Contents for OneStor SP-3584
Page 1: ...OneStor SP 3584 Installation User Guide Part No 83 00007099 10 01 Revision B June 2017 ...
Page 6: ...vi OneStor SP 3584 Installation User Guide ...
Page 8: ...OneStor SP 3584 Installation User Guide viii ...
Page 14: ...OneStor SP 3584 Installation User Guide 6 ...
Page 33: ...Installation 25 Figure 3 4 Valid Configuration ...
Page 64: ...OneStor SP 3584 Installation User Guide 56 ...