54
Barracuda 2LP Product Manual, Rev. D
11 & 12 Delay motor start. Jumper installed causes a
10-second delay for each SCSI ID number
plus a maximum power-up delay of 3 seconds
before starting the spindle motor automati-
cally. Default is no jumper.
Example:
If SCSI ID is equal to three (3)
(3 x 10) +3 = 33
The drive’s spindle motor starts
in 33 seconds.
13 & 14 Reserved
15 & 16 Reserved
17 & 18 Reserved
J4
1
SCSI ID bit 0; no jumper = 0; yes jumper = 1
2
Fault LED pin (-)
3
SCSI ID bit 1; no jumper = 0; yes jumper = 1
4
Vendor unique
5
SCSI ID bit 2; no jumper = 0; yes jumper = 1
6
SSREF(+) spindle sync
7
SCSI ID bit 3; no jumper = 0; yes jumper = 1
8
Unit active LED pin (-)
9
No connection
10
Ground
11
(+) 5 volts
12
No connection
13–20
Reserved
SCSI ID
Bit 3
Bit 2
Bit 1
Bit 0
0
0
0
0
0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
10
1
0
1
0
11
1
0
1
1
12
1
1
0
0
13
1
1
0
1
14
1
1
1
0
15
1
1
1
1
Default SCSI ID = 0
Summary of Contents for BARRACUDA 2LP
Page 2: ......
Page 6: ......
Page 12: ...2 Barracuda 2LP Product Manual Rev D...
Page 14: ...4 Barracuda 2LP Product Manual Rev D...
Page 20: ...10 Barracuda 2LP Product Manual Rev D...
Page 30: ...20 Barracuda 2LP Product Manual Rev D...
Page 42: ...32 Barracuda 2LP Product Manual Rev D...
Page 54: ...44 Barracuda 2LP Product Manual Rev D...
Page 56: ...46 Barracuda 2LP Product Manual Rev D...
Page 68: ...58 Barracuda 2LP Product Manual Rev D...