26
Barracuda 2LP Product Manual, Rev. D
Air-flow cooling
ST31250W and ST32550W wide single-ended drives
MTBF
800k hours
Card
Component
Reference
case temperature (°C)
JYHX
ADC
1
49
JYHX
Detector
2
60
JYHX
Microprocessor
3
55
JYHX
Driver
4
57
The air-flow pattern with which the temperature guidelines above were
generated is shown in Figure 6 (opposite direction). Local average air
velocity was 0.61 msec (120 lfpm) and inlet air temperature to the drive was
30°C (86°F), plus a 5°C temperature rise in the test enclosure (35°C ambient
local to the drive).
The maximum allowable HDA case temperature is 60°C (see Figure 13).
2
3
1
4
Figure 9. JYHX temperature measurement locations