950-0094-revA - 17 - 26 February, 2008
•
If the sleeve is being installed in a wall where the recess is 3” or less, a
flashing must be installed under the sleeve and extend up 2” on each side. The
flashing must include a drip rail as shown in Fig 9.
6. Electrical Requirements
•
Provisions should be made to have a proper electrical outlet near the sleeve.
All wiring must be made in accordance with local codes and national electrical
codes. The line cord included with the chassis (if used) will extend to a wall
receptacle located within the area shown in Fig 10.
ELECTRIC HEATERS
1.
3,000 watt electric heaters have two banks of 1,500 watt heaters. Each electric
heater bank has a UL recognized limit switch set at 120°F.
2.
5,000 watt electric heaters have two banks of 2,500 watt heaters. Each electric
heater bank has a UL recognized limit switch set at 120°F.
3.
All electric heater banks have porcelain insulators securing the heating elements
to the heater frame.
Receptacle
Location
NEMA 6-15R
NEMA 6-20R
NEMA 6-30R