LONG-TERM STOP AND MAINTENANCE

 

The disassembly and/or stop and /or maintenance of the VELA automation system must be carried out by skilled and expert 
technicians. 

GUARANTEE LIMITS

VELA system is guaranteed for 24 months, starting from the date stamped on the product. The product is covered by the 
guarantee provided that the damaged was not caused by inappropriate use, changes or tampering.
The warranty shall be valid only for the original buyer. 

NOTE: THE MANUFACTURER SHALL NOT SHOULDER ANY RESPONSIBILITIES IN CASE OF DAMAGE CAUSED BY 
INAPPROPRIATE, WRONG OR CARELESS USE. 

SEA reserves the right to make all the necessary changes and modifications of the products and / or manuals without giving prior 
notice

STORAGE

STORAGE TEMPERATURE

T

min

-30°C

T

max

+60°C

Humidity

min

5% without condensation

Humidity

max

90% without condensation

When being transported this product must be properly packaged and handled with care.

English

Sistemi Elettronici

di Apertura Porte e Cancelli

International registered trademark n. 804888

®

To the attention of users and technicians 

ARRANGEMENTS 

Read attentively the installation manual as it gives important indications concerning safety, installation, use and 
maintenance.    

Installation, maintenance, reparation, controls and eventual putting out of function of the product must be executed 
by qualified staff only.          

  

For the security of people it is important to follow with attention all the advises and instructions in this 
manual. A wrong installation or a wrong use of the product can cause sever damages to people.

2  

The max. length of the power supply cable between control unit and motors is 10m, use cables with 2,5 mm
section. 

Use wirings with double insulated cables (cables with sheath) up to the immediate proximities of the terminals 
especially for the power supply   cable (230V ).

The control unit must not be used by people (including children) whose physical, sensory or mental ability is reduced, 
or with lack of experience or knowledge, unless they are guarded or have been instructed on how to use the control 
unit by a person respondsible for their safety.   Children must be guarded to make sure   that they don't play with the 
control unit.    

Foresee on the power supply net of the automation a device that assures the complete omnipolar disconnection from 
the net, with a distance of opening of the contacts on each pole of at least 3mm. Those devices of disconnection have 
to be foreseen on the power supply net accordingly to the rules of installation, and they have to be directly connected 
to the power supply terminals.       

It is necessary to keep in adequate distance (at least 2.5 mm in the air) the low tension conductors (230V ) from the 
very low tension conductors (SELV) or to use a suitable sheath of at least 1 mm which supplies an additional 
insulation.    

Make sure that   during installation   the power supply and interconnection cables cannot come into contact with 
pointed or sharp extremities.       

~

~

Cod. 67410035                                                        Rev 06 - 06/2010                                                              

26

Summary of Contents for VELA

Page 1: ...rol of the present inertial force in case of lack of power supply and a release system allows the manual opening in case of emergency The automation system is composed of the following elements 1 Adjustable mechanical stop 2 Manual release with DIN key 3 Galvanised steel rocker arm 4 VELA casing cover with lock and DIN key 5 Balancing spring 6 Electronic control unit GATE 1 code 23001120 1 a compl...

Page 2: ... cod 23001120 1 Technical features Overall dimensions 85 B am rotation axis 0 e Round beam profile Rectangular beam profile English INSTALLATION INSTRUCTIONS 1 Spring position Thanks to its high flexibility the barrier you are installing can be closed on the right hand or left hand side of the post according to your needs e g if the spring is on the right hand side the guard closes on the left see...

Page 3: ...g m i Conduit 500 0 30 2 Foundation plate anchoring Make a 500 x 500 x 300 mm depth hole in the ground Widen the foundation plate clamps till they reach approx 60 Fig 3 Fill the hole with R425 concrete and place the foundation plate as shown in Fig 3 Accurately level the plate The middle hole of the plate must be used for cable routing Therefore make sure that the conduit connected to the hole com...

Page 4: ...010 3 7 mm 11902020 3 5 8 mm 11902005 3 5 8 mm 11902015 Opening times Pump Opening time 1 7 5 s 1 5 5 0 s 2 3 5 s 2 speed 2 5 s 4 Fixing of the spring on the rocker arm Insert with care the roller bearing C in the buckle B and execute the assemblage as Fig 5 Lubricate with grease the bearing and the washers Mount the resting devices as shown in Fig 5 At the end of installation take off the breathe...

Page 5: ... meters Insert the bracket of beam anchorage in vertical position and fix it with the special screw and washer Insert the beam on the bracket and fix it with the special screws the washers and the nuts Fig 7 Attention Before inserting the bracket of anchorage insert the screws of anchorage into the same Tightening screw and washer Beam anchoring bracket Round beam Grooved shaft beam anchoring brac...

Page 6: ...Note For 4 and 5 m beams it is recommended to use the fork support or the flexible support Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 English Fig 9 Cod 67410035 Rev 06 06 2010 20 ...

Page 7: ...7 Mounting of the skirt on the beam Fig 10 Fig 11 English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 Cod 67410035 Rev 06 06 2010 21 ...

Page 8: ...Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 Fig 12 Fig 13 English Mounting of the skirt on the oval beam Cod 67410035 Rev 06 06 2010 22 ...

Page 9: ...g obtained the balancing lock the nuts of the spring stretcher with the counter nut and re block the motor Spring nut stretching Anchoring lock nut 10 Beam levelling Note this operation must be carried out only if the beam is not perfectly horizontal closing stage or vertical opening stage at the end of its stroke Release the beam with the special manual release so that it is free to open and clos...

Page 10: ... 4 Key switch Key Plus 5 Radio receiver 6 Flashing light Flash 7 Push button station 8 Differential switch Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 1 1 2 2 4 4 5 5 6 6 7 7 8 8 2x1 2x1 2x1 4x1 3x1 5 3x1 Fig 17 3 3 3x1 GHOST 40 GHOST 50 ACCESSORIES FOR VELA FORK SUPPORT FEXLIBLE SUPPORT ONLY BEAM it is reccommended to mount with beams which are lon...

Page 11: ...lease operate as follwos Turn the protection cap of the lock Insert the key into the same and turn it about 180 into anti clockwise direction until the beam is released Fig 18 Open manually the beam To re lock operate as follows Turn the key into clockwise direction until it s blocked Fig 19 Extract the key in vertical position Re close the protection cap Fig 18 Fig 19 180 PERIODICALMAINTENANCE Ch...

Page 12: ...ortant to follow with attention all the advises and instructions in this manual Awrong installation or a wrong use of the product can cause sever damages to people 2 The max length of the power supply cable between control unit and motors is 10m use cables with 2 5 mm section Use wirings with double insulated cables cables with sheath up to the immediate proximities of the terminals especially for...

Page 13: ...ention on the installation Disconnect also possible battery buffers if present Make sure that the earth installation has been correctly made connect all the metallic parts of the closing doors gates etc and all the components of the installation provided with earth terminals Apply all the safety devices photocells sensitive edges etc which are necessary to protect the area from dangers of crushing...

Reviews: