SET
DESCRIPTION
DEFAULT NOTE
Closing
If the photocell is occupied, it reverses the movement in
closing; during the pause, it prevents the reclosing
Opening and closing
If active the photocell blocks the movement as long as it
is busy
;
when released, the opening movement continues
Stop
If the photocell is activated before the Start input, the
Start will be ignored. If it is activated after the Start input,
the photocell will be ignored. If it is activated during
closing, the gate will reopen
Stop and close
In closing, the photocell stops the movement until it is
occupied;
when
released
the
closing
movement
continues
Close
The photocell stops the gate until it is occupied in both
opening and closing; when released, it gives a closing
command (it closes one second after its release)
Pause reload
If activated, the photocell recharges the time of pause
during pause. In closing it reverses the movement
Shadow loop
Until occupied, with open gate, it prevents reclosing. It is
switched off during closing
Delete pause time
If the photocell is activated during opening, pause or
closing, the gate reopens completely and closes without
observing the pause time
Shadow loop RP
(pause reloading)
If the shadow loop is temporarily released, the pause
time is reloaded before closing
Stop and open
If the photocell is activated during opening, the gate
stops and will continue in opening only when the
photocell is released. It is ignored during closing
Normal
Normal N.C. contact
8K2
Active edge protected by a 8K2 resistor
8K2 Double
Allows to connect two 8K2 protected edges
Photo 1 10K
Security edge works as a photocell protected by a 10K
resistor
Photo 1 10K Double
It is possible to connect two photocells protected by a
10K resistor
Opening and closing
Active in opening and closing
Only opening
Active only in opening
Only closing
Active only in closing
Automatic
Limit switch in automatic recognition
Only opening
Active limit-switch in opening only
Only closing
Active limit-switch in closing only
106
DIAGNOSTICS
1 10
Shows last event
(See alarms table)
107
MAINTENANCE CYCLES
100 240000
Setting from 100 to 240000
100000
108
PERFORMED CYCLES
0 240000
Reports the executed cycles. Keep pressed OK to reset
the cycles
0
112
PASSWORD
Note: "0000" setting is
not allowed
Allows the entering of a password blocking the control
unit parameters modification
- - - -
98
PHOTOCELL 2
SHADOW-LOOP2
Opening
and
closing
104
SELECT LIMIT SWITCH
Auto-
matic
102
SECURITY EDGE 1
DIRECTION
Opening
and
Closing
SP MENU
100
SECURITY EDGE 1
Normal
59