English
INSTRUCTIONS FOR THE INSTALLER
General safety warnings
ATTENTION
1
For the safety of the people it is extremely important to follow these instructions.
Improper installation or misuse of the product may cause serious injury.
2
Read the instructions carefully before installing the product
3
Store instructions for future use
4
This product has been designed exclusively for the use indicated herein. Any other use may affect the
operation of the product or be a source of danger.
5
Do not install the equipment in explosive atmosphere: the presence of flammable gases or fumes is a serious
safety hazard.
6
The mechanical parts must be in accordance with EN 12604 and EN 12605.
7
The manufacturer is not responsible for the proper manufacturing of doors that must be automated, as well
as deformations that might occur while using
8
The manufacturer disclaims any responsibility derived from the inappropriate use of the product.
9
For each installation, we recommend using at least one flashing light signal or a signpost on the structure
permanently fixed, in addition to the devices referred to in paragraph 21
10
We accept no responsibility for the safety of operator and the malfunctioning if you use components that
are not original from factory
11
For maintenance, strictly use original parts
12
Do not make any changes in the components that are part of the automatism
13
The installer must provide all information relating to the operation of the system in case of emergency and
provide the user the "User Manual" which is attached to the product.
14
Packing materials (plastic, polystyrene, etc..) should not be within the reach of children as they are potential
sources of danger
15
Do not allow children or persons standing in the vicinity of the installation during its operation
16
Keep out of reach of children any remote controls or pulse transmitters to prevent the automatism from
being operated accidentally.
17
Remove the power supply before performing any installation
18
Have the automated system's mains power supply fitted with a switch or Omni polar thermal-magnetic
circuit breaker with a contact separation of at least 3 mm. We recommend the use of a 6A with pole switch.
19
Make sure that up line from the mains power supply there is a residual current circuit breaker that trips at
0.03A.
20
Make sure that the earth system has been installed correctly.
21
The safety devices such as photocells, safety edges or flashing lights (EN 12978) allow you to protect areas
from possible dangers of crushing, dragging, and shearing.
RULES TO AVOID ACCIDENTS DURING INSTALLATION
The connection of the motor to the power line should be performed only after completion of the installation
described below and only before the operation direction test and check of the limit. The operation direction test
and check of the limit switch should be carried out while maintaining at a safe distance from the crumple zone
of the door.