background image

  

FULL TANK 100   FULL TANK 200

1 A

40 bar

30 bar   

130°C

230 V  (±5%) 50/60 Hz

220 W 

         270 mm                  390 mm

70

 

 

-20°C                   +55°C

640da N

12,5uF

12,8 Kg

15,2 Kg 

Ip55

6 mt

  7 mt

   90° / 125° 

           

FEATURES AND SPECIFICATIONS

The 

FULL TANK

 is a high quality hydraulic operator   for condominium   use for gates with leaf lengths   up to   max. 7 m. 

SA

 

(with lock only in opening)

The lock is guaranteed for leaf lengths up to 180 m with the 100 version and up to   2,20 m with the 200 version. For leaf   lengths 
exceeding 2,20 m it is necessery, in all versions, to install an electric lock.   

 Available in the following versions: 

AC

 

(with lock in opening and closing)

SC

 

(with lock only in closing) 

SB

 

(without lock)

The Full Tank is supplied with by-pass valves for the power regulation in both opening and closing. Electronic adjustable slow down 
in opening and closing with   control board GATE 2. For the European laws and directives actually in force it is strongly recommended 
to use the Safety Gate (device for the reading of the gate position), for reverse in case of obstacle. 

 

 

USING GRAPHIC 

 FULL

 T

ANK OPERA

T

OR 

FULL

 T

ANK 100

7 mt

70

FULL

T

ANK 100

1

.   Shaft cover

2

.   Release 

3

.   Front bracket 

4

.   Rear bracket

5

.   Cylinder

6

.   Electric motor

7

.   Hydraulic pump 

8

.   Exit electric cables  

     

FU LL TAN K

Dimensions (

mm

)

English

English

Dimensions (

mm

)

FULL

T

ANK 200

FULL

 T

ANK 200

6 mt

TECHNICAL FEATURES

Operating temperatures
Thermal protection
M

P

Power supply
Power
Absorbed current
Stroke
Cycles hour (at a temp. of 20°C)
Max working pressure

ax Thrust

Capacitor
Weight

rotection class

Max leaf lenght
Opening degree of the leaf 

CICLES/HOUR

OPERATORS

Max. leaf length

17

Cod. 67410845

Sistemi Elettronici

di Apertura Porte e Cancelli

International registered trademark n. 804888

®

REV 02 - 06/2009

1

1

3

3

4

4

2

2

Fig. 3

Fig. 1

FULL TANK 100

FULL TANK 200

Fig. 2

5

6

7

8

0

1

5

2

0

98

0

27

90

5

6

127

0

21

1

5

39

0

90

65

Summary of Contents for FULL TANK 100

Page 1: ...0861 588344 e mail seacom seateam com WEB SITE www seateam com English English INSTALLATION MANUAL and Security Information HYDRAULIC OPERATOR FOR SWING GATE Cod 67410845 REV 02 06 2009 Sistemi Elettr...

Page 2: ...control board GATE 2 For the European laws and directives actually in force it is strongly recommended to use the Safety Gate device for the reading of the gate position for reverse in case of obstacl...

Page 3: ...evis Attachment Rear attachment Breather screw Pin rear attachment short Brass Pin long Front bracket Shaft Cover End cover Cod 67410845 Sistemi Elettronici di Apertura Porte e Cancelli International...

Page 4: ...rential switch 16A 0 03A 7 Photocell rx 8 Key switch start stop 9 Antenna 10 Column for photocells 11 Warning notice 12 Safety Gate TYPE OF INSTALLATION It is possible to install the FullTank with ope...

Page 5: ...95 100 105 110 120 130 110 90 110 90 106 90 90 100 90 100 90 90 96 90 92 92 250 250 250 250 250 253 245 Max Stroke mm Stroke for 90 mm Total stroke 390 mm max recommended stroke 370 mm a b dmax Max O...

Page 6: ...70 65 95 90 95 90 90 90 250 249 Stroke max mm Stroke for 90 mm Total stroke 270 mm max recommended stroke 250 mm a b Max Opening angle mm mm 356 342 345 336 330 335 319 250 255 265 270 275 275 100 95...

Page 7: ...sporting plate as shown in Fig 9 Mount the release as shown in Fig 10 FULL TANK English English Cod 67410845 Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 80488...

Page 8: ...ed angle of the oscillating bracket 1 risks the possible braking of it INSTALLATION OF THE OSCILLATING REAR BRACKET Adjustable rear bracket with screws Accessory on demand INSTALLATION OF REAR BRACKET...

Page 9: ...the front bracket Fig 15 Attention avoid the welding of the front bracket to the shaft of the hydraulic operator already attached the welding scraps daps could ruin the chromium plating of the shaft F...

Page 10: ...adjust the positive stops in opening act on disk 1 and in closing act on disk 2 Attention The mounting of the mechanical positive stops does not cause the reduction of the shaft stroke Insert the ball...

Page 11: ...he opening and closing forces of the gate so that the diagram of the force is respected present in the regulation EN 12453 Anyway the max thrust force should never be superior of 15 KgF INSTALLATION O...