![SEA USA USER 2 - 24V Manual Download Page 12](http://html.mh-extra.com/html/sea-usa/user-2-24v/user-2-24v_manual_1221338012.webp)
B) Press the “IMP” button till the Led of the colour
which corresponds to the type of installation (single
leaf, double leaf, Encoder) turnes on.
Keep pressed the button “SET” till the departure of the
motors in closing and then release the button.
SELFLEARNING WITH DEFAULT PARAMETERS
A) Select LED 10 of the self-learning through the MENU button, with LED 10 turned on press button SET to choose the function
modality:
- led L20 yellow = double leaf Encoder OFF - led L21 red ON = single leaf Encoder OFF
- led L19 and 20 green and yellow = double leaf Encoder ON - led L19 and 21 green and red = single leaf Encoder ON
B) Once the functioning modality has been chosen hold pressed SET up to the departure of the motors in closing and then release the
button.
A) Press the “Menu” button so that to turn on the LED10
WORKING TIMES SELF LEARNING
Fig. 2
Fig. 7
N
O
BETA
Lock
Release
Fig. 5
BETA
A
M2
M1
Fig. 8
M2
M1
Fig. 9
M2
M1
Fig. 4
Fig. 3
FLIPPER
Fig. 6
FLIPPER
Operator
released
Operator
locked
Note1:
it is not necessary to put a jumper between the STOP, PHOTOCELL and SECURITY EDGE (N.C.) contacts if
they are not used. If they are used during selflearning phase they must stay (N.C.).
Note2:
For the electro-hydraulic it is recommanded to set the learning and the functioning speed on the same value.
1) Make sure that each accessory (photocells, push buttons, and so on) works properly and eventually adjust the leaf
delay.
2)If necessary adjust the self-learning speed through the palm user.
3)Disconnect the power supply (Fig. 1), release the motors (Fig. 2-3) and put the leaves manually next to the stop in
Note3
: If accessories are connected on the BUS, align the photocells before programming, as shown on pag.13
The control unit is pre-set
with the default settings, to learn the working times it is sufficient to press the Menu button once and
to hold pressed the SET buttonuntil the motors start in closing.
The settings of DEFAULT are: SEMIAUTOMATIC LOGIC, DOUBLE LEAF ENCODER OFF, MIDDLE SPEED, LEAF DELAY 3 S., PAUSE 2
S., AVERAGE TORQUE, SLOWDOWN SPEED 30%, LEARNING SPEED 50%, ACCELERATION 70%, DECELARATION 30%, LEAF
STROKE OFF, ANTI-INTRUSION OFF, SELFTEST OFF, PEDESTRIAN 100%, PHOTO OPENING OFF, MAX CYCLES 100000, MOTOR
TYPE: FLIPPER. IF YOU WANT TO RESTORE THE DEFAULT SETTINGS JUST SWITCH ON THE CONTROL UNIT KEEPING PRESSED
THE BOUTONS MENU AND SET CONTEMPORARILY.
Fig. 1
F
F
O
closing (Fig. 4). Reset the mechanical lock (Fig. 5-6)
4) Connect the control board to the power supply (Fig.7).
5) Select the desired type of motor; use as shown on pag. 11 or through JOLLY programmer.
6) Press the button “SET” until the led of the color corresponding to the type of application (single leaf, double leaf, Encoder ON, Encoder OFF)
switches on.
7) Hold pressed the button “SET” until the motors start in closing and then release the button.
Note
: If the motors do not start check the alignment of the FOTOBUS and give an impulse on SET.
Note
: If one or both motors should start in opening remove the power supply and reverse the cables of the motor or the motors which start in
opening. Afterwards repeat the procedure starting from point 4.
8) Both leaves will start the closing with reduced speed (Fig.4).
9) At the attainment of the stops they will automatically execute an opening cycle with reduced speed (Fig.8). After having reached the stop in
opening they will automatically perform a closing cycle.
10) Wait for the end of the closing of the leaf (Fig.9). The self-learning is done.
JOLLY functions
:
1) With the JOLLY programmer
it is possible to start the programming
without using the MENU and SET
bouton.
2) With the JOLLY programmer it is
possible to chose the type of motora and
the type of application without using the
MENU and SET boutons.
67410925
USER 2 - 24V
International registered trademark n. 2.777.971
LED10
LED19
LED20
LED21
SET
MENU
Programming
GREEN
YELLOW
RED
REV 02 - 06/2010
12