ENCODER - LIMIT SWITCH
SECURITY EDGE
ELECTRIC LOCK AND WARNING LAMP
Limit switch
If not connected they don't have to be bridged.
For the limit switch function the presence of the limit
switches in both closing and opening is necessary. In
case of single leaves it is not necessary to bridge the
limit switch of the motor 2.
Encoder / Ammeter sensor
The encoder is a device that allows to reveal possible obstacles during the opening and the closing of
the gate. When this device intervenes in opening it causes the inversion of the movement for around a
second, if it intervenes in closing it causes the total reopening.
Note 1: Such function is active through an ammeter sensor on the control board. It is not
necessary to mount any external devices for the respect of the normative.
Nota2: The ammeter sensitivity is adjustable through the Palmuser modifying the motor torque
parameter for every single leaf. On the control unit the torque can be adjusted in 4 steps: low,
middle, middle high, high and contemporarily on both the motors. With high torque the gate
reverses after 5 seconds.
Attention: after every intervention of the ammeter sensor it is necessary to give a start impulse
to restore the movement.
It is possible to connect an active safety edge on the terminal M13. If
this device is pressed it opens the contact causing a partial inversion
of the movement both in opening and in closing. If not used bridge
the contacts 1 and 2 of M13. Note: contact N.C.
Opening Limit Switch
M2
Closing Limit Switch
M2
Opening Limit Switch M1
Closing
Limit SwitchM1
Encoder M2
Encoder M1
Com
Com
Com
Com
C
C
C
C
1 2 3 4 5
1 2 3 4 5
24V
M11
M14
Br
ow
n
Gr
ee
n
Com
W
te
hi
Br
ow
n
24V
Gr
ee
n
Com
W
hite
For the right function of the
limit switches there must be a
corrsipondence between the
direction of movement of the
motors and the respective
occupied limit switches.
Com = Common
C = Contact
Electric lock exit
An electric lock of 12V 15W max
can be connected .
The electric lock activates at every
opening cycle for about 1,5 s.
1 2
M13
Flashing Lamp 24V 15W (Warning lamp )
The warning lamp advises that the automatic gate is in movement
performing 1 flash /second in opening and 2 flashes / second in
closing. Instead it remains turned on fix during pause.
To connect it, connect the wires of the warning lamp as shown in
the figure.
M6
1 2
1 2
1 2
1 2
M8
Safety edge
JOLLY functions
: With the JOLLY programmer the torque parameters can be adjusted linearly
from 10% to 100% on each single motor. Furthermore, they are differentiable between opening
and closing.
JOLLY functions:
W i t h t h e J o l l y
programmer
such function is
tied up to the presence of at
least one liit is possible to
activate the function anti-
intrusion. Limit switch, that if
released, forces the motor to
re-close.
JOLLY function:
Through
the Jolly programmer it is
possible to disactivate the electric
lock if not used. This operation allows
to save energy of the control unit.
JOLLY functions
: It is possible to activate a pre-flashing
of 3 seconds before activating the automation, on setting
pre-flashing on ON, through the Jolly programmer. Furthermore
from the flashing lamp it is possible to verify some alarm signals.
See alarms indications.
Through the Jolly programmer it is possible to set this exit with fixed
flashing also when the gate is not moving or it is possible to change
this exit into control lamp. In such case all the indications of alarm
remain on the warning lamp as long as they are active.