20.
Two cables may be passed through each of the
Roxtec® Multidiameter® CM-20w40 blocks
provided.
21.
If cables larger than 1.65cm/0.65in outer diameter
will be used, larger single-cable Roxtec®
Multidiameter CM-40 10-32 blocks are available to
allow three cables of up to3.25cm/1.28in diameter
to be used. The
rubber bar
and the
three double-
cable
Roxtec® Multidiameter blocks will be
replaced
by the
three larger Roxtec®
Multidiameter blocks
.
HINT: It may be helpful to put the clamp bar and
rubber bar in place (held loosely by one screw) to
hold some of the Roxtec® Multidiameter blocks in
place while you complete the others.
22.
Re-install the clamp bar using the hardware removed
in step 14 above.
23.
Remove the tag lines.
24.
Remove the lifting sling.
25.
Remove the 4 lifting eye nuts and re-install the
original perimeter bolt hardware (the eyes are
galvanized with bare thread that will rust if left
exposed to the weather). Save the lifting eye
hardware in case lifting of the ADE is required in the
future.
3.4.
Grounding the Pedestal
The antenna pedestal must be grounded to the hull of the ship. A grounding point is provided on the upper base plate
to ground the pedestal. You must provide a cable, or strap, that is of sufficient gauge and length to ground the
pedestal to the nearest grounding point of the hull (this is usually on or near the mounting surface).
Solid strap
is the conductor of choice for low impedance RF ground connections because the RF currents tend to
flow along the outer surface and the strap has a large, smooth, surface area to take full advantage of this effect.
Braid
is the conductor of choice where flexibility is required. Sea Tel uses braid to cross axes of the antenna pedestal
and to connect various subassemblies together.
Wire
is the easiest to install, the easiest to connect and is readily available with a weather protective jacket. 4 awg and
6 awg bare solid copper wire is commonly used as safety grounds and very basic lightning protection grounds. 2 awg
stranded wire is often used for lightning grounding and bonding and it much more flexible.
Summary of Contents for 5012-33
Page 3: ...iii RTT E Declaration Page Testing Being Conducted...
Page 4: ...iv FCC Declaration Testing Being Conducted...
Page 8: ...5012 33 Installation Manual Table of Contents viii This Page Intentionally Left Blank...
Page 20: ...5012 33 Installation Manual Site Survey 2 8 This Page Intentionally Left Blank...
Page 34: ...5012 33 Installation Manual Installation 3 14 This Page Intentionally Left Blank...
Page 44: ...5012 33 Installation Manual Setup Ship s Gyro Compass 5 4 This Page Intentionally Left Blank...
Page 54: ...5012 33 Installation Manual Setup Blockage Zones 8 2 This Page Intentionally Left Blank...
Page 64: ...5012 33 Installation Manual Quick Start Operation 10 6 This Page Intentionally Left Blank...
Page 80: ...5012 33 Installation Manual DRAWINGS 13 2 This Page Intentionally Left Blank...
Page 90: ......
Page 91: ......
Page 92: ......
Page 98: ......