6.23
S
ECTION
6 • E
LECTRICAL
S
YSTEM
320 Sundancer
®
(355 Sundancer
®
)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
PORT
IGNITION
STBD
IGNITION
ACCESSORY
REFRIG
DISCHARGE
PUMP
HEAD
SYSTEM
POWER
VENTS
WATER
PUMP
STEREO
LIGHTING
DISCHARGE
BILGE
BLOWERS PREHEAT/ON START/RUN
GENERATOR
WASTE
LEVEL
FULL
DO NOT
FLUSH
1/2
EMPTY
ON
8
10
12
14
16
WARNING
GASOLINE VAPORS CAN EXPLODE
RESULTING IN INJURY OR DEATH
BEFORE STARTING ENGINES
- CHECK ENGINE COMPARTMENTS BILGE
FOR GASOLINE OR VAPORS AND
- OPERATE BLOWERS FOR FOUR MINUTES, AND
- VERIFY BLOWER OPERATION
RUN BLOWER WHEN VELLEL IS OPERATING BELOW
CRUISE SPEEDS
C.O. MONITOR
PORT
MASTER IGNITION
STBD
12 VOLT DC
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
STOVE
0
10 20
30
40
120 VOLT AC
OUTLETS/
REFRIGERATOR
WATER HEATER
AC CONVERTER
MICROWAVE
AIR CONDITIONER
ON
OFF
ON
OFF
POWER
REVERSED
POLARITY
50
GENERATOR
SHORE
MAIN
2.
In The Engine Room:
A. Open generator seacock.
B. *Smell for fuel fumes.
C. Check generator oil and coolant levels.
See generator operator’s manual for proper
readings.
*DANGER, Gasoline Vapors Can Explode.
Al-
ways check engine room by visual inspection and
smell. Do not start the generator or engines until
the source of fumes is determined and corrected
and the engine room is safely ventilated.
On The Boat:Cabin 12 Volt DC Panel:
C. Turn ON bilge blowers. Run blowers for 4
minutes prior to starting. Leave blowers on
when generator is on.
A. S
TARTING
T
HE
G
ENERATOR
(Remote control switches are located on the main
distribution panel or local switches on the
generator.)
To start the generator and turn on generator
power:
1.
On The Boat:
A. Check fuel tank levels.
On The Boat:120 Volt or 220 Volt AC MDP:
B. Ensure GENERATOR main breaker is OFF.
Pre-start generator prior to getting underway as there
is a possibility that it will not pick up water if started
underway. Make sure the MAIN GENERATOR breaker
is OFF and there is no load on the generator before
starting it.
NOTICE
DO NOT run the engine or generator in an enclosed
area, such as a closed boat house, as there is the
possibility of buildup and inhaling of carbon
monoxide.
!
WARNING
E
F
Fuel
Note: The power panels on your boat may not look exactly like these.
C
120 V or 220 V AC
A
(B) *Smell For
Fuel Fumes
(C) Check Fluid
Levels
(A) Generator
Seacock
M
AIN
D
ISTRIBUTION
P
ANEL
(MDP) (F
IG
. 6.23.2)
C
ABIN
DC D
ISTRIBUTION
P
ANEL
(F
IG
. 6.23.3)
Note: The power panels on your boat may not look exactly like these.
A
B
C
(F
IG
. 6.23.1)
(F
IG
. 6.23.4)
B
Summary of Contents for 320 Sundancer
Page 1: ...320 Sundancer Owner s Manual Part Number MRP1803608 Sea Ray Owner s Manual...
Page 2: ......
Page 4: ...320 Sundancer 355 Sundancer ii...
Page 30: ...1 18 SECTION 1 SAFETY 320 Sundancer 355 Sundancer THIS PAGE LEFT INTENTIONALLY BLANK...
Page 34: ...1 22 320 Sundancer 355 Sundancer THIS PAGE LEFT INTENTIONALLY BLANK...
Page 62: ...3 12 SECTION 3 USING YOUR BOAT 320 Sundancer 355 Sundancer THIS PAGE LEFT INTENTIONALLY BLANK...
Page 88: ...5 6 SECTION 5 FUEL SYSTEM 320 Sundancer 355 Sundancer THIS PAGE LEFT INTENTIONALLY BLANK...