4.3 – CONNECTION TO THE DMX CHAIN
Use a cable conforming to specifications EIA RS-485: pole twisted, shielded, 120 Ohm
characteristic impedance and low capacity (SAGITTER SG DMX3 – SG DMX5).
Do not use microphone cable or other cable with different characteristics than those
specified. Terminations must be made with male / female XLR 3-pin connectors. You must
enter on the last device a terminal plug with a 120Ohm resistance (min 1/4 W) between
terminals 2 and 3.
IMPORTANT: The cables must not come into contact with each other or with the metal
housing of the connectors. The housing itself must be connected to the shield braid and to
pin 1 of the connectors.
5. - SETUP
Open oil tank, and then refill the fog liquid inside. In order to keep the smoke oil
cleaning, please immediately cover the tank after refilling the smoke liquid.
Insert the power cable in the outlet with earth wire, press the ON/OFF button, the
smoke machine starts to heat. During the heating, display shows
“Heating %”
. When the
heating is finished display shows
“Machine Ready”
.
It is possible to use the machine in 2 different modes (Hazer and Smoke) selectable via
the relative button on the display (A)
HAZER MODE = button released
SMOKE MODE = button pressed
A