Mounting Instructions 5 Pad Non Illuminated:  KP-2U

1.  Select flat mounting surface 3" X 7".

2.  Use “Template A” (included with the Keypad) to mark locations of holes A, B, and C.

3.  Locate and drill the large hole marked “A”. Hole must be at least 

" (22mm) diameter.

4.  Hold the Keypad against the wall with the connector through hole “A”. Check markings for hole “B”.   Re-mark if 

required. If using plastic anchors, drill hole “B” using 

3

/

16

" (6mm) bit. NOTE: Plastic anchors are provided for some 

mounting applications. If anchors are not used, holes “B” and “C” must be smaller than 

3

/

16

".

5.  Using the template, verify the hole marked “C” is aligned and then drill hole “C”.

6.  Install the metal mounting bracket into hole “C” with the screw provided.

7.  Do NOT mount Keypad at this time.

8.  Proceed to Install the Wiring Cable.

Mounting Instructions 12 Pad 3x4: KP-4U

The 3x4 keypad is designed to mount to a single gang switchbox or on a wall, pedestal or any flat surface of at least 
3 ½” by 5 ¼”.  The composition of the mounting surface will determine the fastening method required.  If mounting to 
a surface other than a switchbox:

1.   Select a flat surface (3 ½” by 5 ¼”) near the door where you wish to install the keypad.

2.   Drill the large hole for the Keypad connector using a 

” (25mm) drill bit.

3.   Place the connector on the back of the keypad in the large hole. Mark the keypad mounting holes.  

4.   Drill clearance holes in accordance with fastening method used.  (If mounting to wood, drill small pilot holes and 

use #6 flat head wood screws provided.  If mounting to metal, drill two 

5

/

32

" clearance holes for  #6 flat head 

machine screws provided.)

5.   Do NOT mount the keypad at this time.

6.   Proceed to Install the Wiring Cable.

P:\INSTALLATION INST\Access Control\INST-931.vsd     0505     Page 6

Mounting Instructions Thinline 2x6: KP-3U and KP-34

The KP3 2x6 is designed for mullion mount applications.  It can also be mounted on a wall, pedestal or any flat 
surface of at least 1 ¾” by 7”.  The composition of the mounting surface will determine the fastening method required:

1.   Select a flat surface (1 ¾ ” by 7”) near the door where you wish to install the keypad.

2.   Using the Thinline template, mark location of holes. 

3.   Drill the large hole using a 1” (25mm) drill bit.

4.   Place the connector on the back of the keypad in the large hole to verify that the mounting holes are aligned.  

Make adjustments if necessary. 

5.   Drill mounting holes in accordance with fastening method used. If mounting to wood, drill small pilot holes and 

use #6 flat head wood screws provided.  If mounting to metal, drill two 

5

/

32

" clearance holes for #6 flat head 

machine screws provided.

6.   Do NOT mount the keypad at this time.

7.   Proceed to Install the Wiring Cable.

Summary of Contents for EntryCheck 931-KP-2U

Page 1: ...ryCheck The 931 EntryCheck is an easy to program easy to use stand alone self contained system with features suitable for basic access control requirements Providing either a voltage output or dry con...

Page 2: ...NG THE LOCKING DEVICE 7 BATTERY BACK UP 7 SYSTEM HARDWARE SETUP 8 REMOTE BY PASS 8 ANTI TAILGATING 8 SETTING RELAY OPTIONS 8 9 TAMPER ALARM LOCKOUT 9 SYSTEM PROGRAMMING 10 OVERVIEW OF SYSTEM CODE PROG...

Page 3: ...Length 6 Codes 1 Master 5 User of User Codes 1 3 5 7 9 Default Master Code 25 Incorrect Key Presses Tamper Alarm Non Volatile Memory Access Code Protection 40 C to 70 C 40 F to 160 F 100 Relative Humi...

Page 4: ...e configured to perform one of many different functions depending on the specific access control requirement User Authorization to control each relay is determined by Setting Relay Options see System...

Page 5: ...ble may be spliced The maximum distance between the Keypad and the Control Module must not exceed 1 000 feet For runs over 200 feet 18 gauge wire should be used Under 200 feet 20 gauge is acceptable 4...

Page 6: ...25mm drill bit 3 Place the connector on the back of the keypad in the large hole Mark the keypad mounting holes 4 Drill clearance holes in accordance with fastening method used If mounting to wood dri...

Page 7: ...ch system are two MOV s metal oxide varistor The function of the MOV is to absorb any inductive kickback from the locking device protecting the circuit board The MOV s have been installed under the re...

Page 8: ...p the MONITOR screw terminals with factory installed wire SETTING RELAY OPTIONS The 931 provides a variety of options for configuring both relays These options include User Unlock Authorization Latchi...

Page 9: ...Authorization relay for that particular User Group will energize and remain energized until a valid code followed by 7 is entered again Ex Latching Authorization P INSTALLATION INST Access Control INS...

Page 10: ...9 However the Master Code cannot be configured to Latch either relay PROGRAMMING THE MASTER CODE To Program Change the Master Code 1 Select a 3 to 8 digit code that will be used for the Master Code _...

Page 11: ...for every one second increment and 5 s for every five second increment that equal your desired Door Open Time Each valid key press a 1 or a 5 will generate a double beep Do not let more than five sec...

Page 12: ...and you will have to start over For an existing Installation There are typically two reasons for code loss static or inductive kickback There is no way to determine if the system has been affected by...

Page 13: ...APPENDIX A CIRCUIT BOARD LAYOUT P INSTALLATION INST Access Control INST 931 vsd 0505 Page 13...

Page 14: ...r relay to eliminate chatter Fail Secure Lock Fail Safe Lock Controlled by KE 265 Controlled by KE 265 CCTV DOORBELL and Fail Secure Lock Garage Door Gate Drive Controlled by KE 265 Controlled by KE 2...

Page 15: ..._________ Master Code 2 User Name__________________________ Master Code 3 User Name__________________________ Master Code 4 User Name__________________________ Master Code 5 P INSTALLATION INST Access...

Reviews: