SYSTEM SPECIFICATIONS
Input Requirements:
12 to 24V AC/DC
1 to 120 seconds
Default 5 seconds
Latching:
Programmable Output
(Door Open Time)
2 SPDT Relay contacts at 6 Amps (120VAC)
Voltage or Dry Contact
Fail Safe or Fail Secure Replay Configuration
Outputs:
Standby Current Draw:
12V 10 mA
24v 25mA
Manual (Toggle On/Off)
3 to 8 Digits
Code Length:
6 Codes (1 Master, 5 User)
# of User Codes:
1-3-5-7-9
Default Master Code:
25 Incorrect Key Presses
Tamper Alarm:
Non-Volatile Memory
Access Code Protection:
-40°C to + 70°C (-40°F to + 160°F)
100 % Relative Humidity
Keypad Operating Environment:
KP-2U 6
⅝
" x 2
¼
” x
½
"
KP-4U 5
⅛
" x 3
⅜
” x
7
/
16
"
KP-3U, KP-3Y 7
⅛
" x 1
¾
” x
¾
"
Keypad Dimensions:
5 Pad Non Illuminated
12-Pad 3x4
Thinline 2x6
-40°C to + 49°C (-40°C to + 120°F)
100 % Relative Humidity
Control Module Operating
Enviroment:
7
½
" x 5
½
" x 2
½
"
Control Module Dimensions:
P:\INSTALLATION INST\Access Control\INST-931.vsd 0505 Page 3